2021-06-02 09:32:081ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 21050364
 6/2/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: THE PLUMBING SYSTEMS FOR THE PROPOSED
 PROJECT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE
 WITH THE FBC- 2020 7TH EDITION RESIDENTIAL CODE. PLEASE
 REVISE THE INCORRECT COMPLIANCE DATA AND CODE SECTIONS
 SPECIFIED IN THE NOTES- SECTION 107.2.1 WPB.
  
 2) P1: UNDER NOTE #17 PLEASE INCLUDE THE COMPLIANCE AND
 CONFORMANCE DATA FOR THE BATH TUB VALVE- SEE SECTION
 P2713.3 FBC RES.
  
 3) P1.1: PLEASE ADD THE SLOPE OF THE FINISHED SHOWER
 FLOOR TO THE DETAIL- 1/4 UNIT VERTICAL IN 12 UNITS
 HORIZONTAL (2-PERCENT SLOPE) NOR MORE THAN 1/2 UNIT
 VERTICAL PER 12 UNITS HORIZONTAL (4-PERCENT SLOPE)-
 SECTION P2709.1 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  