| Plan Review Notes For Permit 21041612 |
| Permit Number |
21041612 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-05-13 15:38:52 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) PROVIDE DETAILED STRUCTURAL DRAWINGS FOR THE NEW | | | FOUR FOOT HIGH WALL. SPECIFY THE MATERIALS THAT WILL BE | | | USED TO CONSTRUCT THE WALL. FOR 8" X 16" CONCRETE | | | BLOCK, SPECIFY THE SIZE AND SPACING OF THE VERTICAL | | | STEEL REINFORCING FOR THE CONCRETE FILLED CELLS. | | | SPECIFY THE STEEL REINFORCING IN THE CONCRETE FILLED | | | TIE BEAM AND SPECIFY THE SIZE OF THE TIE BEAM. SPECIFY | | | HOW THE VERTICAL REBARS WILL BE ANCHORED INTO THE | | | EXISTING WALL. FBC 107.2.1 | | | | | | 2) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | |
|