Notes
Date Text
2021-06-28 15:58:18RESTAURANT RENO
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW ANY NEW CEILING DETAILS -HEIGHT AND TYPE
 - FBC 1208.2
 2) PLEASE SHOW NEW RESTROOM FLOORING AND WALL BASE TO
 COMPLY WITH FBC 1210.2.1 FLOORS AND WALL BASES.
 IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND
 SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH
 FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE
 WALLS NOT LESS THAN 4 INCHES
 3) ON MULTIPLE DRAWINGS THE CODE USED FOR DESIGN IS THE
 2017 FBC ( CODE USED FOR THE DESIGN SHOULD BE 2020 FBC)
 - PLEASE REVISE THE DRAWINGS TO SHOW THE CORRECT CODE
 IN EFFECT.
 4) PLEASE SHOW THE ACCESSIBLE SEATING SPACES TO COMPLY
 WITH FBC ACCESSIBILITY 226.1 GENERAL.
 WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION
 OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING
 SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL
 COMPLY WITH 902.
 5) PLEASE SHOW THE ACCESSIBLE SEATING SPACE AT THE BAR
 TO COMPLY WITH FBC 902 - FBC ACCESSIBILITY 902.2 CLEAR
 FLOOR OR GROUND SPACE.
 A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A
 FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE
 CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
 (PROVIDE KNEE AND TOE CLEARANCE DETAILS)
 6) PLEASE SHOW THE HEIGHT OF THE ACCESSIBLE BAR SEATING
 TO COMPLY WITH FBC 902.3 HEIGHT.
 THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE
 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  