| Date |
Text |
| 2021-06-28 15:58:18 | RESTAURANT RENO |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| | AMENDMENTS |
| | |
| | CORRECTIONS NEEDED - |
| | 1) PLEASE SHOW ANY NEW CEILING DETAILS -HEIGHT AND TYPE |
| | - FBC 1208.2 |
| | 2) PLEASE SHOW NEW RESTROOM FLOORING AND WALL BASE TO |
| | COMPLY WITH FBC 1210.2.1 FLOORS AND WALL BASES. |
| | IN OTHER THAN DWELLING UNITS, TOILET, BATHING AND |
| | SHOWER ROOM FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE. THE INTERSECTIONS OF SUCH |
| | FLOORS WITH WALLS SHALL HAVE A SMOOTH, HARD, |
| | NONABSORBENT VERTICAL BASE THAT EXTENDS UPWARD ONTO THE |
| | WALLS NOT LESS THAN 4 INCHES |
| | 3) ON MULTIPLE DRAWINGS THE CODE USED FOR DESIGN IS THE |
| | 2017 FBC ( CODE USED FOR THE DESIGN SHOULD BE 2020 FBC) |
| | - PLEASE REVISE THE DRAWINGS TO SHOW THE CORRECT CODE |
| | IN EFFECT. |
| | 4) PLEASE SHOW THE ACCESSIBLE SEATING SPACES TO COMPLY |
| | WITH FBC ACCESSIBILITY 226.1 GENERAL. |
| | WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION |
| | OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING |
| | SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL |
| | COMPLY WITH 902. |
| | 5) PLEASE SHOW THE ACCESSIBLE SEATING SPACE AT THE BAR |
| | TO COMPLY WITH FBC 902 - FBC ACCESSIBILITY 902.2 CLEAR |
| | FLOOR OR GROUND SPACE. |
| | A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A |
| | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE |
| | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | (PROVIDE KNEE AND TOE CLEARANCE DETAILS) |
| | 6) PLEASE SHOW THE HEIGHT OF THE ACCESSIBLE BAR SEATING |
| | TO COMPLY WITH FBC 902.3 HEIGHT. |
| | THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE |
| | 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |