| Plan Review Notes For Permit 21041524 |
| Permit Number |
21041524 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-05-12 11:17:21 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) BUILDING CONSTRUCTION TYPE SHOWN AS (IV) - PLEASE RE | | | EVALUATE THE BUILDING CONSTRUCTION TYPE - (IV) IS HEAVY | | | TIMBER. | | | 2) PLEASE SHOW FIRE RATED DOORS TO AUTOMATICALLY CLOSE | | | AND LATCH PER FBC 716.5.9 | | | 3) PLEASE SHOW THE WALL OPENING DIMENSION BETWEEN THE | | | RECEPTION AREA AND THE OPEN OFFICE AREA. FBC 1005.4 |
|