| 2021-07-23 16:50:24 | 4TH REVIEW FBC-2020 RES. BUILDING. |
| | PERMIT- 21041480 |
| | 7/23/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | RESULTS: DENIED. AFTER REVIEWING THE COMMENT BELOW |
| | PLEASE CONTACT ME FOR ASSISTANCE. |
| | |
| | 1) THE NEW SUBMITTED NOA- 20-0131.01 FOR FLINTASTIC SBS |
| | MODIFIED SELF ADHERING ROOF FOR WOOD- NON-INSULATED |
| | ROOFS REQUIRES ADDITIONAL ENGINEERING FOR INSTALLATION. |
| | YOU HAVE SELECTED THE SYSTEM ON PAGE 11 WHICH HAS TWO |
| | DIFFERENT TYPE OF DECK ATTACHMENTS- DECK 1 OR 2. DECK 1 |
| | IS RATED AT -52.5 PSF, AND DECK 2 IS RATED AT -60 PSF. |
| | TABLE 301.2(2) FBC RES. INDICATES -78 PSF FOR ZONE 3 |
| | (CORNER ZONES) WHICH INDICATES GENERAL LIMITATION #7 |
| | WILL APPLY. PLEASE REFER TO PAGE 18 AND GENERAL |
| | LIMITATION NOTE #7- PERIMETER AND CORNER AREAS SHALL |
| | COMPLY WITH THE ENHANCED UPLIFT PRESSURE REQUIREMENTS |
| | OF THESE AREAS. FASTENER DENSITIES FOR THE BASE SHEET |
| | AS CALCULATED IN COMPLIANCE WITH RAS 117. CALCULATIONS |
| | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED |
| | PROFESSIONAL ENGINEER, ARCHITECT, OR REGISTERED ROOF |
| | CONSULTANT. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | BUILDING PLANS EXAMINER |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH, FL. 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |