| Date |
Text |
| 2021-05-12 16:31:00 | 1ST REVIEW FBC-2020 RES. PLUMBING. |
| | PERMIT- 21041463 |
| | 5/12/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) A-1 & S-1: THE PLUMBING RISER DOES NOT INCLUDE THE |
| | NEW KITCHEN SINK- SECTION 107.3.5.3 WPB. |
| | |
| | 2) A-1: PROVIDE THE MAKE, MODEL NUMBER, GALLON SIZE, |
| | AND EFFICIENCY RATING OF THE NEW WATER HEATER- TABLE |
| | C404.2 FBC EC. CLARIFY IF THE WATER IS ELECTRIC OR |
| | GAS-FIRED- SECTION 107.2.1 WPB. |
| | |
| | 3) A-1: PROVIDE A SHOWER PAN DETAIL- SECTION P2709.1 & |
| | P2709.2 FBC RES. |
| | |
| | 4) A-1: INDICATE HOW WATER WILL BE PROVIDED TO THE |
| | GUEST HOUSE- SECTION P2602.1 FBC RES. |
| | |
| | 5) PLEASE NOTE THAT TWO SEPARATELY ADDRESSED DWELLING |
| | UNITS ON THE SAME LOT MAY REQUIRE INSTALLATION OF A |
| | BACKFLOW PREVENTION ASSEMBLY AT THE POINT OF DELIVERY. |
| | THE TYPE OF BACKFLOW ASSEMBLY REQUIRED WILL BE |
| | DEPENDENT UPON THE DEGREE OF HAZARD POSED BY THE WATER |
| | USER. A REDUCED PRESSURE ZONE BACKFLOW DEVICE WILL BE |
| | NEEDED FOR THE WATER METER PER THE CITY OF WEST PALM |
| | CROSS UTILITIES DEPARTMENT AND THEIR CONNECTION CONTROL |
| | PROGRAM. PLEASE NOTE THAT A FL. LICENSED PLUMBING |
| | CONTRACTOR SHALL OBTAIN A SEPARATE PERMIT FOR |
| | INSTALLATION OF THE BACKFLOW PREVENTER IN ACCORDANCE |
| | WITH SECTION 105.1 WPB AND SEC. 90-33 WPB CODE OF |
| | ORDINANCES. THE DEVICE SHALL BE TESTED AND CERTIFIED BY |
| | THE WPB UTILITIES DEPARTMENT PRIOR TO FINAL INSPECTION |
| | BY THE BUILDING DEPARTMENT. PLEASE CONTACT THE WPB |
| | UTILITIES CENTRAL OPERATIONS DEPT.AT 561-822-2210 FOR |
| | FURTHER INFORMATION. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |