| 2021-06-21 15:30:47 | WINDOWS/DOORS SUBMITTAL, THIRD BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | SUBMITTAL #21041230 |
| | |
| | ORIGINAL COMMENT: |
| | 1- WINDOW PRODUCT APPROVAL WAS CHANGED TO DOUBLE HUNG |
| | FLORIDA PRODUCT APPROVAL FL14477-R5. THIS PRODUCT |
| | APPROVAL DOESN'T INCLUDE A WINDOW SIZE SCHEDULE. PLANS |
| | SPECIFY SH25 EGRESS WINDOWS FOR THE SECOND FLOOR |
| | BEDROOMS. |
| | TYPICALLY, A SH25 SINGLE HUNG HAS A SIZE OF +/-37" |
| | WIDTH BY +/-63" HEIGHT. BASED ON THE KOLBE & KOLBE |
| | MILLWORK COMPANY WEBSITE IT LOOKS LIKE THIS SIZE OF |
| | WINDOW MAY NOT COMPLY WITH THE EGRESS REQUIREMENTS FOR |
| | THE SECOND FLOOR BEDROOMS. |
| | PROVIDE MANUFACTURER'S CUT SHEETS SHOWING THAT THE |
| | SPECIFIED WINDOW SIZE COMPLIES WITH THE EGRESS |
| | REQUIREMENTS. CLEARLY SHOW SIZE OF WINDOW AND ALL CLEAR |
| | OPENINGS: WIDTH, HEIGHT AND TOTAL CLEAR OPENING. IF |
| | SIZE OF WINDOW NEEDS TO BE REVISED, THEN REVISE PLANS |
| | ACCORDINGLY. |
| | SEC. R310.2.1 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | SOFIA FROM RJS BUILDERS SPECIFIED WINDOW "O" SIZE IS: |
| | 37.5"W X 64 7/16"H. |
| | BASED ON THE KOLBE & KOLBE MILLWORK COMPANY WEBSITE |
| | THIS SIZE OF WINDOW DOESN'T COMPLY WITH THE EGRESS |
| | REQUIREMENTS FOR THE SECOND FLOOR BEDROOMS. |
| | THE CLEAR HEIGHT FOR THIS WINDOW IS 20-7/16" AND THE |
| | TOTAL CLEAR OPENING IS 4.82S.F. (SEE ATTACHED |
| | SCREENSHOT). NEED MINIMUM OF 24 CLEAR HEIGHT OPENING |
| | AND MINIMUM CLEAR OPENING OF 5.7S.F. |
| | ENGINEER OF RECORD NEEDS TO REVISE PLANS SPECIFYING |
| | SIZE OF WINDOW COMPLYING WITH ALL THE EGRESS |
| | REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. |
| | NOTE: CLEARLY SPECIFY SIZE OF WINDOW (WIDTH AND HEIGHT) |
| | THAT MATCHES WINDOW MANUFACTURER?S PUBLISHED SIZES. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |