| Date |
Text |
| 2021-05-14 15:13:56 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT-21041220 |
| | 5/14/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET P1.1: REVISE THE DRAWING TO SHOW A WALL HUNG |
| | TOILET- SECTION 425.1 FBC P. |
| | |
| | 2) P1.1: INDICATE THE TYPES AND SIZES OF FM PIPING- |
| | SECTION 712.3.3.3.1 FBC P. |
| | |
| | 3) P1.1: 712.2 SHOW THE LOCATIONS OF THE CHECK VALVE |
| | AND FULL OPEN VALVE IN THE SANIFLOW DISCHARGE PIPING- |
| | SECTION 712.2 FBC P. INDICATE HOW ACCESS WILL BE |
| | PROVIDED TO THE VALVES. |
| | |
| | 4) P1.1: INDICATE WHICH SIDE OF THE WALL WILL HAVE THE |
| | SANIFLOW ACCESS PANEL AND PROVIDE PANEL DIMENSIONS- |
| | SECTION 107.2.1 WPB. |
| | |
| | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS AND |
| | INSTALLATION MANUALS FOR THE SANIFLOW SANIPACK AND |
| | LIBERTY PUMPS WITH APPROVAL STAMPS BY THE DESIGN |
| | PROFESSIONALS OF RECORD- SECTIONS 712.3- 712.4.2 FBC P. |
| | THE APPROVED SPECS AND MANUALS MAY BE DEFERRED AND BUT |
| | MUST BE ONSITE AT TIME OF INSPECTION- SECTION 107.3.4.1 |
| | WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |