| Date |
Text |
| 2021-09-08 16:11:56 | FAILED - THIS DOES NOT COUNT AS A RESUBMITTAL REVIEW. |
| | ZONING WILL DO NO FURTHER REVIEWS UNTIL THE REQUIRED |
| | MINOR PLANNED DEVELOPMENT AMENDMENT IS SUBMITTED AND |
| | REVIEWED FOR APPROVAL. |
| | |
| | 1) REPEAT COMMENT: THE PROPERTY IS ZONED RESIDENTIAL |
| | PLANNED DEVELOPMENT, SO THE ADDITION OF THE ELECTRIC |
| | VEHICLE CHARGER MODIFIES THE APPROVED SITE PLAN AND A |
| | MINOR PLANNED DEVELOPMENT AMENDMENT IS REQUIRED PRIOR |
| | TO ZONING APPROVAL OF THIS PERMIT. PLEASE CONTACT THE |
| | PLANNING DIVISION FOR DETAILS. |
| | UPDATED: ONCE THE MINOR PLANNED DEVELOPMENT AMENDMENT |
| | IS SUBMITTED TO THE PLANNING DIVISION AND APPROVED; THE |
| | APPROVED PLANS ARE THEN SUBMITTED AS PART OF THE |
| | BUILDING PERMIT APPLICATION. |
| | |
| | A. THE MINOR AMENDMENT WILL REQUIRE A SITE PLAN SHOWING |
| | THE LOCATION OF THE PROPOSED VEHICLE CHARGING STATION. |
| | UPDATED: THE SURVEY THAT WAS PROVIDED MAY BE USED AS |
| | THE SITE PLAN. HOWEVER, THE SURVEY WAS NOT MARKED TO |
| | INDICATED WHERE THE CHARGING STATION WILL BE LOCATED, |
| | AND WHICH NUMBERED PARKING SPACES WILL BE USED FOR THE |
| | CHARGING SPACES. THE ELECTRIC SITE PLANS DO NOT MATCH |
| | THE SURVEY. THE ELECTRIC PLANS LIST THE LOCATION OF THE |
| | CHARGING STATION NEXT TO BUILDING 12 YET BUILDING 12 |
| | DOES NOT HAVE THE POOL OR MAINTENANCE BUILDING NEXT TO |
| | IT. ACCURATE INFORMATION MUST BE PROVIDED. |
| | |
| | B. A BLOW UP WILL BE REQUIRED OF THE SPECIFIC PLACEMENT |
| | OF THE CHARGER AT THE HEAD OF THE SPACES, TO INCLUDE |
| | SCALED DIMENSIONS. STAFF NEEDS TO BE ABLE TO VERIFY |
| | THAT THE PLACEMENT OF THE PROPOSED CHARGING STATION |
| | DOES NOT RENDER EITHER OF THE PARKING SPACES |
| | NON-COMPLIANT FOR SIZE OR IMPEDE THE SIDEWALK. THE |
| | PHOTO AND SHEET E1.0 LAYOUT DO NOT PROVIDE ADEQUATE |
| | DETAIL. |
| | UPDATE: REVISED SHEET E1.0 IS NOT DRAWN TO SCALE AND |
| | DOES NOT ACCURATELY SHOW THE CHARGER CONFIGURATION, THE |
| | REQUIRED DOUBLE STRIPED PARKING (AND THE CHARGER'S |
| | RELATIONSHIP TO THE STRIPING, OR CODE COMPLIANT PARKING |
| | SPACES. NOTE: THE CITY HAS NEVER PERMITTED |
| | EIGHT-FOOT-WIDE BY TWELVE-FOOT-DEEP PARKING SPACES. THE |
| | MINIMUM CITY PARKING SPACE DIMENSION IS 8.5 FEET WIDE |
| | BY 18 FEET IN LENGTH. A QUICK REVIEW OF THE CHARGER |
| | SIZE SEEMS TO INDICATE THAT THE CHARGER CAN FIT BETWEEN |
| | THE DOUBLE STRIPING IF IT IS EXACTLY CENTERED IN THE |
| | DOUBLE STRIPING, BUT YOU NEED TO PROVIDE THE DETAILS. |
| | *** STAFF CAN PROVIDE THE STANDARD CITY PARKING DETAIL |
| | UPON REQUEST. |
| | |
| | C. BASED ON THE INFORMATION ON THE CHARGING STATION |
| | USERS, THE MINOR AMENDMENT IS REQUIRED TO PROVIDE A |
| | PARKING TABLE FOR THE OVERALL SITE. THE PARKING TABLE |
| | NEEDS TO INCLUDE THE NUMBER OF REQUIRED RESIDENT AND |
| | GUEST SPACES MEETING CITY CODE AS WELL AS THE NUMBER OF |
| | RESIDENT AND GUEST SPACES PROVIDED. THE PARKING SPACES |
| | THAT ARE USED FOR THE CHARGING STATION MAY NOT BE |
| | REQUIRED AND ASSIGNED PARKING SPACES FOR RESIDENTS OR |
| | GUESTS, WHICH ONCE ASSIGNED AS CHARGING STATION SPACES |
| | WOULD RESULT IN A PARKING DEFICIENCY. |
| | UPDATE: THANK YOU FOR PROVIDING THE SURVEY WHICH |
| | ENUMERATES THE TOTAL PARKING SPACES ON THE SITE. NO |
| | TABLE WAS PROVIDED LISTING HOW MANY UNITS ARE IN THE |
| | DEVELOPMENT WITH THE CORRESPONDING NUMBER OF REQUIRED |
| | RESIDENT AND GUEST PARKING SPACES AND HOW MANY RESIDENT |
| | AND GUEST PARKING SPACES ARE PROVIDED. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |