| 2021-07-06 08:49:58 | RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21040514 |
| | |
| | ORIGINAL COMMENT: |
| | 1- DRAWINGS SUBMITTED ARE TOO SMALL AND ARE NOT |
| | LEGIBLE. DRAWINGS HAVE A COPY OF THE ARCHITECT'S |
| | DIGITAL SIGNATURE AND WERE REDUCED TO 8-1/2 X 11 PAGES. |
| | DRAWINGS NEED TO HAVE ARCHITECT'S ORIGINAL SEAL AND |
| | SIGNATURE WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS |
| | AS REQUIRED BY 61G1-16.003 FAC. THERE ARE TWO WAYS TO |
| | SUBMIT THE DRAWINGS. ONE IS TO UPLOAD THE DRAWINGS TO |
| | PROJECTDOX WITH THE ARCHITECT'S DIGITAL SIGNATURE OR |
| | THE OTHER OPTIONS TO SUBMIT FULL SCALE DRAWINGS WITH |
| | THE ARCHITECT'S ORIGINAL SEAL/SIGNATURE. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. PLANS SUBMITTED ARE NOT SIGNED AND |
| | SEALED BY THE ARCHITECT OF RECORD. |
| | |
| | ORIGINAL COMMENT: |
| | 2-PROVIDE COMPLETE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR: |
| | A)SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS. |
| | RESPONSE: |
| | REPEAT COMMENT. COMPLETE PRODUCT APPROVAL WAS NOT |
| | SUBMITTED. |
| | |
| | B)HORIZONTAL SLIDING WINDOWS AS SPECIFIED ON PLANS. |
| | RESPONSE: |
| | REPEAT COMMENT. COMPLETE PRODUCT APPROVAL WAS NOT |
| | SUBMITTED. |
| | |
| | C)HURRICANE SHUTTERS AND COMPLETE INSTALLATION SINCE |
| | WINDOWS DON'T HAVE IMPACT GLASS. YOU MAY USE THE CITY |
| | SAMPLE FOR HURRICANE SHUTTERS INSTALLATION SCHEDULE OR |
| | PROVIDE COMPLETE INFORMATION IN ANY OTHER FORMAT. |
| | RESPONSE: |
| | REPEAT COMMENT. INFORMATION WAS NOT SUBMITTED. |
| | NOTE: SINGLE HUNG WINDOWS AND HORIZONTAL ROLLING |
| | WINDOWS UPLOADED TO PROJECTDOX ON 04/09/21 WERE FOR |
| | NON-IMPACT WINDOWS. ARCHITECT SPECIFIES IMPACT WINDOWS. |
| | COORDINATE PRODUCT APPROVALS WITH ARCHITECT'S |
| | SPECIFICATIONS TO AVOID CONFLICTS/DELAYS. |
| | |
| | D)HARDIE PLANK LAP SIDING AS SPECIFIED ON PLANS. |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT. |
| | 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | RESPONSE: |
| | SINGLE HUNG WINDOWS AND HORIZONTAL ROLLING WINDOWS |
| | UPLOADED TO PROJECTDOX ON 04/09/21 WERE FOR NON-IMPACT |
| | WINDOWS. ARCHITECT SPECIFIES IMPACT WINDOWS. COORDINATE |
| | PRODUCT APPROVALS WITH ARCHITECT'S SPECIFICATIONS TO |
| | AVOID CONFLICTS/DELAYS. |
| | |
| | NEW COMMENTS BASED ON PLANS THAT ARE LEGIBLE NOW: |
| | 4- WINDOW DESIGN PRESSURES CALCULATED BY THE ARCHITECT |
| | ARE TOO LOW. ACCORDING TO TABLE R301.2(2) |
| | FBC-RESIDENTIAL AND CORRESPONDING HEIGHT AND EXPOSURE |
| | COEFFICIENT FOR EXPOSURE "C" ON TABLE R301.2(3) |
| | FBC-RESIDENTIAL THE DESIGN PRESSURES SPECIFIED BY THE |
| | ARCHITECT OF RECORD ARE TOO LOW. ARCHITECT OF RECORD TO |
| | REVISE DESIGN PRESSURES ON THE WINDOW/DOOR SCHEDULE OR |
| | PROVIDE ACTUAL CALCULATIONS. (NOTE: WORST CASE SCENARIO |
| | IS FOR THE LOWEST OPENING EFFECTIVE WIND AREA LOCATED |
| | IN THE END ZONE). |
| | SEC. 107.2.1.2 CITY AMENDMENTS. |
| | |
| | 5-WINDOW SILL DETAIL AND FRAME WALL SECTION SHOWN ON |
| | SHEET G0.1 DON'T MATCH. THE WINDOW SILL DETAIL IS FOR |
| | EIFS WALLS. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 |
| | CITY AMENDMENTS. |
| | |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |