Plan Review Notes
Plan Review Notes For Permit 21040514
Permit Number 21040514
Review Stop B
Sequence Number 2
Notes
Date Text
2021-07-06 08:49:58RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21040514
  
 ORIGINAL COMMENT:
 1- DRAWINGS SUBMITTED ARE TOO SMALL AND ARE NOT
 LEGIBLE. DRAWINGS HAVE A COPY OF THE ARCHITECT'S
 DIGITAL SIGNATURE AND WERE REDUCED TO 8-1/2 X 11 PAGES.
 DRAWINGS NEED TO HAVE ARCHITECT'S ORIGINAL SEAL AND
 SIGNATURE WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS
 AS REQUIRED BY 61G1-16.003 FAC. THERE ARE TWO WAYS TO
 SUBMIT THE DRAWINGS. ONE IS TO UPLOAD THE DRAWINGS TO
 PROJECTDOX WITH THE ARCHITECT'S DIGITAL SIGNATURE OR
 THE OTHER OPTIONS TO SUBMIT FULL SCALE DRAWINGS WITH
 THE ARCHITECT'S ORIGINAL SEAL/SIGNATURE.
  
 RESPONSE:
 REPEAT COMMENT. PLANS SUBMITTED ARE NOT SIGNED AND
 SEALED BY THE ARCHITECT OF RECORD.
  
 ORIGINAL COMMENT:
 2-PROVIDE COMPLETE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 A)SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS.
 RESPONSE:
 REPEAT COMMENT. COMPLETE PRODUCT APPROVAL WAS NOT
 SUBMITTED.
  
 B)HORIZONTAL SLIDING WINDOWS AS SPECIFIED ON PLANS.
 RESPONSE:
 REPEAT COMMENT. COMPLETE PRODUCT APPROVAL WAS NOT
 SUBMITTED.
  
 C)HURRICANE SHUTTERS AND COMPLETE INSTALLATION SINCE
 WINDOWS DON'T HAVE IMPACT GLASS. YOU MAY USE THE CITY
 SAMPLE FOR HURRICANE SHUTTERS INSTALLATION SCHEDULE OR
 PROVIDE COMPLETE INFORMATION IN ANY OTHER FORMAT.
 RESPONSE:
 REPEAT COMMENT. INFORMATION WAS NOT SUBMITTED.
 NOTE: SINGLE HUNG WINDOWS AND HORIZONTAL ROLLING
 WINDOWS UPLOADED TO PROJECTDOX ON 04/09/21 WERE FOR
 NON-IMPACT WINDOWS. ARCHITECT SPECIFIES IMPACT WINDOWS.
 COORDINATE PRODUCT APPROVALS WITH ARCHITECT'S
 SPECIFICATIONS TO AVOID CONFLICTS/DELAYS.
  
 D)HARDIE PLANK LAP SIDING AS SPECIFIED ON PLANS.
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT.
 3- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
 RESPONSE:
 SINGLE HUNG WINDOWS AND HORIZONTAL ROLLING WINDOWS
 UPLOADED TO PROJECTDOX ON 04/09/21 WERE FOR NON-IMPACT
 WINDOWS. ARCHITECT SPECIFIES IMPACT WINDOWS. COORDINATE
 PRODUCT APPROVALS WITH ARCHITECT'S SPECIFICATIONS TO
 AVOID CONFLICTS/DELAYS.
  
 NEW COMMENTS BASED ON PLANS THAT ARE LEGIBLE NOW:
 4- WINDOW DESIGN PRESSURES CALCULATED BY THE ARCHITECT
 ARE TOO LOW. ACCORDING TO TABLE R301.2(2)
 FBC-RESIDENTIAL AND CORRESPONDING HEIGHT AND EXPOSURE
 COEFFICIENT FOR EXPOSURE "C" ON TABLE R301.2(3)
 FBC-RESIDENTIAL THE DESIGN PRESSURES SPECIFIED BY THE
 ARCHITECT OF RECORD ARE TOO LOW. ARCHITECT OF RECORD TO
 REVISE DESIGN PRESSURES ON THE WINDOW/DOOR SCHEDULE OR
 PROVIDE ACTUAL CALCULATIONS. (NOTE: WORST CASE SCENARIO
 IS FOR THE LOWEST OPENING EFFECTIVE WIND AREA LOCATED
 IN THE END ZONE).
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 5-WINDOW SILL DETAIL AND FRAME WALL SECTION SHOWN ON
 SHEET G0.1 DON'T MATCH. THE WINDOW SILL DETAIL IS FOR
 EIFS WALLS. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1
 CITY AMENDMENTS.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]