Plan Review Notes
Plan Review Notes For Permit 21040197
Permit Number 21040197
Review Stop B
Sequence Number 1
Notes
Date Text
2021-04-20 09:02:39SPIRAL STAIR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) DRAWINGS ARE UNCLEAR - PLEASE PROVIDE A CLEAR COPY
 OF THE DRAWINGS.
 2) PLEASE SHOW HANDRAIL HEIGHT TO COMPLY WITH FBC
 R311.7.8.1 HEIGHT.
 HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED
 PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF
 RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM)
 AND NOT MORE THAN 38 INCHES (965 MM).
 3) PLEASE SHOW HANDRAIL/GUARDRAIL OPENINGS TO COMPLY
 WITH FBC R312.1.3 OPENING LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE
 WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT ALLOW
 PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER.
 EXCEPTIONS:
 1.THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIR,
 FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD,
 SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES (153 MM)
 IN DIAMETER.
 2.GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE
 OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4 3/8 INCHES
 (111 MM) IN DIAMETER.
 4) DRAWINGS ARE UN CLEAR CANNOT SEE THESE MEASUREMENTS
 - FBC R311.7.10.1 SPIRAL STAIRWAYS.
 SPIRAL STAIRWAYS ARE PERMITTED, PROVIDED THAT THE CLEAR
 WIDTH AT AND BELOW THE HANDRAIL IS NOT LESS THAN 26
 INCHES (660 MM) AND THE WALKLINE RADIUS IS NOT GREATER
 THAN 241/2 INCHES (622 MM). EACH TREAD SHALL HAVE A
 DEPTH OF NOT LESS THAN 63/4 INCHES (171 MM) AT THE
 WALKLINE. ALL TREADS SHALL BE IDENTICAL, AND THE RISE
 SHALL BE NOT MORE THAN 91/2 INCHES (241 MM). HEADROOM
 SHALL BE NOT LESS THAN 6 FEET 6 INCHES (1982 MM).
 5) DRAWINGS ARE UNCLEAR - PLEASE SHOW CONNECTION TO THE
 BUILDING AND FOUNDATION - FBC R311.5.1 ATTACHMENT.
 EXTERIOR LANDINGS, DECKS, BALCONIES, STAIRS AND SIMILAR
 FACILITIES SHALL BE POSITIVELY ANCHORED TO THE PRIMARY
 STRUCTURE TO RESIST BOTH VERTICAL AND LATERAL FORCES OR
 SHALL BE DESIGNED TO BE SELF-SUPPORTING. ATTACHMENT
 SHALL NOT BE ACCOMPLISHED BY USE OF TOENAILS OR NAILS
 SUBJECT TO WITHDRAWAL.
 6) PLEASE PROVIDE A SITE PLAN SHOWING THE LOCATION OF
 THE STAIR.
 7) JOB VALUE SHOWN ON THE PERMIT APPLICATION NEEDS TO
 INCLUDE THE COST OF THE STAIR - WHICH IS NOT SHOWN ON
 THE CONTRACT PROVIDED. FOR PERMITTING PURPOSES THE
 VALUE OF ALL LABOR AND MATERIALS REQUIRED TO COMPLETE
 THE PROJECT ARE REQUIRED TO BE INCLUDED IN THE COST.
 FBC 109.3
 8) DRAWINGS APPEAR TO BE FOR AN INTERIOR STAIR. IF
 STAIR IS FOR THE EXTERIOR IT IS SUBJECT TO WIND LOADS -
 PLEASE SHOW THE WIND DESIGN CRITERIA TO COMPLY WITH FBC
 R301.1.3 ENGINEERED DESIGN.
 WHERE A BUILDING OF OTHERWISE CONVENTIONAL CONSTRUCTION
 CONTAINS STRUCTURAL ELEMENTS EXCEEDING THE LIMITS OF
 SECTION R301 OR OTHERWISE NOT CONFORMING TO THIS CODE,
 THESE ELEMENTS SHALL BE DESIGNED IN ACCORDANCE WITH
 ACCEPTED ENGINEERING PRACTICE. THE EXTENT OF SUCH
 DESIGN NEED ONLY DEMONSTRATE COMPLIANCE OF
 NONCONVENTIONAL ELEMENTS WITH OTHER APPLICABLE
 PROVISIONS AND SHALL BE COMPATIBLE WITH THE PERFORMANCE
 OF THE CONVENTIONAL FRAMED SYSTEM. ENGINEERED DESIGN IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING IS
 PERMITTED FOR BUILDINGS AND STRUCTURES, AND PARTS
 THEREOF, INCLUDED IN THE SCOPE OF THIS CODE. PLEASE
 SHOW THE WIND DESIGN CRITERIA PER FBC 1603.1.4
  