| Date |
Text |
| 2021-06-15 11:26:32 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): |
| | 1. REVISE DOOR TO HAVE CLEAR GLASS ONLY. PROPOSED DOOR |
| | IS NOT APPROPRIATE. REVISE TO BE A 15-LITE DOOR OR |
| | OTHER VARIANT. ANOTHER OPTION IS A 4-LITE 1/4 WITH TWO |
| | VERTICAL PANELS BELOW. ANOTHER OPTION IS CREATING A |
| | 6-LITE PATTERN TO THE PROPOSED DOOR. VARIATIONS OF |
| | THESE MAY BE ACCEPTABLE. |
| | 2. INSUFFICIENT INFORMATION PROVIDED. PROVIDE ALL |
| | PHOTOS OF THE EXISTING WINDOWS. |
| | 3. INSUFFICIENT INFORMATION PROVIDED. PHOTOS INDICATING |
| | THE EXISTING CONDITION DO NOT INDICATE WHICH WINDOW OR |
| | WINDOWS THAT THIS DAMAGE IS ON NOR DOES IT INDICATE |
| | THAT THE WINDOW CANNOT BE REPAIR. PROVIDE ADDITIONAL |
| | INFORMATION. ONLY AN EXPERIENCED WINDOW RESTORATION |
| | INDIVIDUAL OR COMPANY CAN MAKE THE DETERMINATION OF |
| | FIXABILITY. |
| | 4. CONFIRM THAT THE MARVIN PRODUCT IS THE CURRENT |
| | PRODUCT. SIW WINDOWS MAKES THEIR OWN WINDOWS. PROVIDE |
| | MUNTIN DETAIL. |
| | |
| | PROPOSED CONDITIONS, SUBJECT TO CHANGE. CONFIRM THAT |
| | THE PROPOSED PRODUCT(S) WILL COMPLY WITH THESE |
| | CONDITIONS. |
| | 1. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE |
| | ORIGINAL WINDOW FRAME OPENING (X-AXIS AND Y-AXIS) AND |
| | MATCH THE LOCATION/DEPTH (Z-AXIS) OF THE ORIGINAL |
| | WINDOWS. |
| | 2. THE EXISTING MULLION SHALL REMAIN OR BE REPLACED |
| | WITH A MULLION OF MATCHING WIDTH AND PLACEMENT. |
| | 3. ALL STREET OR SIDEWALK FACING GLASS SHALL BE CLEAR. |
| | ALL NON-STREET FACING GLASS SHALL BE CLEAR OR CLEAR |
| | WITH LOW-E COATING. NO TINT. OBSCURED TEXTURED GLASS |
| | MAY BE USED ON NON-STREET FACING BATHROOMS ONLY. |
| | |
| | AARON BORNGRABER, AICP |
| | HISTORIC PRESERVATION PLANNER | DEVELOPMENT SERVICES |
| | PLANNING DIVISION |
| | [email protected] | OFFICE: 561.822.1428 | TTY: |
| | 800.955.8771 |
| | 401 CLEMATIS STREET | P.O BOX 3147 | WEST PALM BEACH, |
| | FL 33402 |
| | |