Plan Review Notes
Plan Review Notes For Permit 21031585
Permit Number 21031585
Review Stop P
Sequence Number 1
Notes
Date Text
2021-04-07 10:33:111ST REVIEW FBC-2017 PLUMBING
 REVISION PERMIT- 21031585
 4/7/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A1.3: THE SUBMITTED PLAN SHEET IS LACKING
 REVISION 1 AND 2 CHANGES- 8.13.20, 2.11.21 WHICH
 INCLUDED AMONG OTHER THINGS, THE PLUMBING FIXTURE
 CALCULATIONS AND THE PLUMBING FIXTURE SCHEDULE. PLEASE
 REVIEW THE APPROVED PLAN SHEET UNDER PERMIT 20041058
 AND PROVIDE A COMPLETELY UPDATED PLAN SHEET- SECTION
 107.2.1 WPB.
  
 2) SHEET P1.1: DETAIL 4 FOR THE MOP SINKS IS MISLABELED
 AS A FLOOR SINK. PLEASE SEE SECTION 1210.2.2 FBC B FOR
 REQUIRED FLOOR AND WALL FINISHES AT THE MOP SINK.
 TYPICALLY MOP SINKS ARE DIRECTLY CONNECTED TO THE
 GREASE WASTE LINE HOWEVER THE PLANS SHOW FLOOR SINKS
 BELOW THEM. THE INDIRECT CONNECTION APPEARS TO BE A
 MISTAKE- PLEASE CLARIFY.
  
 3) P1.5: PLEASE LABEL THE MOP SINK CORRECTLY. IT
 APPEARS TO BE LABELED AS A FLOOR SINK- SECTION 107.2.1
 WPB.
  
 4) NEW KITCHEN PLANS HAVE BEEN SUBMITTED THAT SHOW
 EQUIPMENT WHICH WILL REQUIRE WATER SUPPLY CONNECTIONS.
 PLEASE PROVIDE A WATER RISER DRAWING SHOWING SUPPLY
 LINE SIZES, POINT OF CONNECTION, AND LOCATIONS OF
 VALVES, WATER HAMMER ARRESTORS AND BACKFLOW PREVENTERS-
 SECTION 107.3.5.3 WPB, AND SECTIONS 604.1, 604.9, &
 608.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  