| 2021-04-08 10:48:36 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT-21031169 |
| | 4/8/2019 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THE PLUMBING PLANS ARE NOT ACCEPTABLE FOR COMPLETE |
| | REVIEW AND PERMIT ISSUANCE. PLEASE REVISE THE PLANS AND |
| | PROVIDE: |
| | |
| | A) PLUMBING SCOPE OF WORK FOR THE KITCHEN, BATHROOMS, |
| | AND LAUNDRY ROOM- SECTION 107.2.1 WPB. |
| | B) SANITARY DRAINAGE VENT ISOMETRIC DRAWINGS FOR THE |
| | KITCHEN, BATHS, AND LAUNDRY ROOM- SECTION 107.3.5.3 |
| | WPB. |
| | C) DIMENSIONED FLOOR PLAN DRAWING THAT SHOWS THE |
| | LOCATIONS OF ALL NEW AND REPLACED PLUMBING FIXTURES. |
| | PLEASE INCLUDE SHOWER DIMENSIONS IN ACCORDANCE WITH |
| | SECTION 421.4 FBC P. |
| | D) SHOWER PAN DETAILS- SECTION 421.5 FBC P. |
| | E) SLAB REPAIR DETAIL- SECTION 107.2.1 WPB. |
| | |
| | 2) THE CONTRACTOR OR QUALIFIER WHO PREPARES THE REVISED |
| | PLUMBING DRAWING SHALL PROVIDE HIS/HER PRINTED NAME, |
| | PROJECT ADDRESS, AND WET SIGNATURE ON IT- SECTION |
| | 107.2.1 WPB, AND FLORIDA STATUTES 471.003(2)(H) & |
| | 471.025. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |