Plan Review Notes For Permit 21031072
Permit Number 21031072
Review Stop B
Sequence Number 2
Notes
Date Text
2022-03-25 16:34:44PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. COMPLETE.
  
 2. COMPLETE.
  
 3. PROVIDE DESIGN WIND PRESSURES. PLACE ON ROOF PLAN.
 WIND DESIGN CRITERIA:
 BASIC WIND SPEED = 170 VULT/132 ASD 3 SECOND GUST.
 EXPOSURE = C
 STRUCTURE IS DESIGNED AS OPEN
  
 4. PROVIDE A ROOF SHEATHING FASTENER SCHEDULE.
 19/32" OR GREATER PLYWOOD ATTACHED WITH 8D RING SHANK
 NAILS PER FASTENER SCHEDULE:
 USE FIGURE R301.3 (7) (GABLE AND FLAT ROOF) DIAGRAM.
 INCLUDE THE WIND LOAD SCHEDULE AND PLYWOOD SHEATHING
 NAILING SCHEDULE IN YOUR REVIEW NOTES.
 PLACE THIS INFO ON THE ROOF PLAN.
 PRINT YOUR NAME AND SIGN IT.
  
 UPLOAD TO DRAWINGS FOLDER IN PROJECT DOX.
  
  
 NOTICE: ROOFING PERMIT REQUIRED. SEE ROOFING REVIEW
 COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  