| Date |
Text |
| 2021-04-14 15:16:12 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER PX3169 1&2 FAMILY - SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: CITY POLICY REQUIRES A SEPERATE PERMIT FOR EACH |
| | STRUCTURE ON AN INDIVIDUAL PARCELL. SUBMIT PERMIT |
| | APPLICATION FOR GUEST HOUSE. ALL PLANS WILL REMAIN |
| | UNDER MAIN HOUSE PERMIT 21030992. |
| | SEPERATE INSPECTIONS WILL BE REQUIRED. SEPERATE C/O |
| | WILL BE ISSUED. |
| | |
| | 1. PROVIDE FINISHED FLOOR ELEVATION. |
| | R403.1.7.3 FOUNDATION ELEVATION. |
| | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| | ALL LOCATIONS ON THE SITE. |
| | |
| | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION |
| | PLAN AND/OR FLOOR PLAN. |
| | |
| | 2. PROVIDE SITE DRAINAGE PLAN. |
| | FBC R401.3 SITE DRAINAGE |
| | PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH |
| | FBC R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. |
| | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| | INCHES WITHIN THE FIRST 10 FEET. |
| | |
| | 3. SOILS REPORT NOT REQUIRED. PROVIDE DENSITY TEST AT |
| | FOUNDATION INSPECTION. |
| | |
| | REF. PRODUCT APPROVAL AFFIDAVIT FOR THE FOLLOWING: |
| | |
| | 4. THE FOLLOWING PRODUCT APPROVALS ARE MISSING THE |
| | COVER LETTER. THE COVER SHEET PROVIDES THE APPROVAL |
| | NUMBER, CODE VERSION, AND STATUS, FBC R 301. |
| | FL17184.1 |
| | |
| | 5. THE FOLLOWING PRODUCT APPROVALS ARE NOT LISTED ON |
| | THE PRODUCT APPROVAL AFFIDAVIT. DESIGNER SHALL REVIEW |
| | AND APPROVE THE FOLLOWING: |
| | FL16709-R7, FL6332-R9, FL11288-R18. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |
| | |
| | |