| 2021-11-15 12:59:26 | SFR ADDITION AND SEPARATE GARAGE (PERMITS 21030892 AND |
| | 21060942) |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected]. |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| | |
| | 1) ROOFING PRODUCT APPROVAL PROVIDED FOR THE LIQUID |
| | ROOFING SYSTEM STATES THAT "THIS IS NOT A WATER |
| | PROOFING SYSTEM" SEE NOTE NUMBER 4 ON THE PRODUCT |
| | APPROVAL (NOA18-0321.09) - MANUFACTURES NOTES - PLEASE |
| | PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE PRODUCT |
| | APPROVALS FOR THE ROOFING SYSTEMS. (TILE AND LOW SLOPE |
| | ROOF DECKS) |
| | |
| | 2) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE |
| | PRODUCT APPROVAL NUMBERS NEED TO BE SHOWN ON THE |
| | DRAWINGS. |
| | |
| | 3) PLEASE SHOW ROOF DRAINAGE SYSTEM ON THE ROOF PLAN TO |
| | COMPLY WITH FBC R903.4 |
| | |
| | 4) PLEASE SHOW THE REQUIRED OVERFLOW SCUPPERS TO COMPLY |
| | WITH FBC R903.4.1 |
| | |
| | 5) PLEASE SHOW ROOF VENTILATION TO COMPLY WITH FBC |
| | R806.1 |
| | |
| | 6) PLEASE SHOW THE STEP RISER HEIGHT AND TREAD DEPTH TO |
| | COMPLY WITH FBC R311.7.5 |
| | |
| | 7) PLEASE SHOW TUB AND SHOWER WALL AREAS TO COMPLY WITH |
| | FBC R702.4.2 |
| | |
| | 8) PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH |
| | FBC R401.3 DRAINAGE. |
| | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED BOUNDARY LINE SURVEY. |
| | FBC R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN |
| | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE |
| | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE |
| | FIRST 10 FEET (3048 MM). |
| | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| | PERCENT AWAY FROM THE BUILDING. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |