Plan Review Notes
Plan Review Notes For Permit 21030892
Permit Number 21030892
Review Stop B
Sequence Number 3
Notes
Date Text
2021-11-15 12:59:26SFR ADDITION AND SEPARATE GARAGE (PERMITS 21030892 AND
 21060942)
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
  
 1) ROOFING PRODUCT APPROVAL PROVIDED FOR THE LIQUID
 ROOFING SYSTEM STATES THAT "THIS IS NOT A WATER
 PROOFING SYSTEM" SEE NOTE NUMBER 4 ON THE PRODUCT
 APPROVAL (NOA18-0321.09) - MANUFACTURES NOTES - PLEASE
 PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE PRODUCT
 APPROVALS FOR THE ROOFING SYSTEMS. (TILE AND LOW SLOPE
 ROOF DECKS)
  
 2) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE
 PRODUCT APPROVAL NUMBERS NEED TO BE SHOWN ON THE
 DRAWINGS.
  
 3) PLEASE SHOW ROOF DRAINAGE SYSTEM ON THE ROOF PLAN TO
 COMPLY WITH FBC R903.4
  
 4) PLEASE SHOW THE REQUIRED OVERFLOW SCUPPERS TO COMPLY
 WITH FBC R903.4.1
  
 5) PLEASE SHOW ROOF VENTILATION TO COMPLY WITH FBC
 R806.1
  
 6) PLEASE SHOW THE STEP RISER HEIGHT AND TREAD DEPTH TO
 COMPLY WITH FBC R311.7.5
  
 7) PLEASE SHOW TUB AND SHOWER WALL AREAS TO COMPLY WITH
 FBC R702.4.2
  
 8) PROVIDE A SITE DRAINAGE PLAN SHOWING COMPLIANCE WITH
 FBC R401.3 DRAINAGE.
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN
 SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE
 SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE
 FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
  
  
  
  
  
  
  
  
  