| Date |
Text |
| 2021-04-08 16:47:08 | 1ST REVIEW FBC-2020 RES. |
| | PERMIT- 21030892 |
| | 4/8/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET P-1: UPDATE THE FBC- 2017 CODE REFERENCE IN |
| | NOTE #1. THE FBC-2020 7TH EDITION CODES WENT INTO |
| | EFFECT ON 12/31/2020. |
| | |
| | 2) P1 NOTES: PLEASE PROVIDE PLUMBING PIPING |
| | SPECIFICATIONS FOR ABOVE AND UNDERGROUND INSTALLATIONS- |
| | SECTION P2609.1 FBC RES. |
| | |
| | 2) P1: THE SAN. RISER SHOWS A NON-COMPLIANT WET VENT IN |
| | THE COMMON BATHROOM. NOT MORE THAN ONE WET-VENTED |
| | FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF THE |
| | DRY-VENTED FIXTURE DRAIN CONNECTION- SECTION P3108.2.1 |
| | FBC RES. |
| | |
| | 3) P1: PROVIDE SHOWER PAN DETAILS- SECTIONS P2709.1 & |
| | P2709.2 FBC RES. |
| | |
| | 4) P1: PROVIDE WALL AND FLOOR FINISH DETAILS FOR THE |
| | SHOWER AND BATHTUB- SECTION R307.2 FBC RES. |
| | |
| | 5) P2: INDICATE THE TYPE OF UNDERGROUND WATER PIPING |
| | AND HOW IT WILL BE PROTECTED FROM CORROSION- SECTION |
| | P2603.3 FBC RES. |
| | |
| | 6) P2: SHOW LOCATIONS OF WATER HAMMER ARRESTORS FOR |
| | WATER SUPPLY LINES TO THE WASHING MACHINE, DISHWASHER, |
| | AND ICE MAKER LINE- SECTION P2903.5 FBC RES. |
| | ALTERNATELY PLEASE PLACE A NOTE ON THE PLAN TO CLARIFY. |
| | |
| | 7) SUBMIT A PLUMBING SUB-PERMIT APPLICATION- SECTION |
| | 105.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |