| Plan Review Notes For Permit 21030706 |
| Permit Number |
21030706 |
|
| Review Stop |
NFIP |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-03-26 14:25:49 | PLAN REVIEW / NFIP | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER BUILDING - PX3169 | | | PLANS EXAMINER 1&2 FAMILY - SFP306 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | CODES IN EFFECT: | | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4729-17 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | FINISHED CONSTRUCTION ELEVATION CERTIFICATE | | | | | | 1. SECTION A9 | | | FLOOD OPENINGS SHALL BE LOCATED ON AT LEAST TWO | | | ADJACENT WALLS OR DOORS. SEE COMMENTS UNDER BUILDING | | | REVIEW. | | | | | | 2. SECTION C2(A)-BASED ON FEMA LOWEST FLOOR GUIDE, THE | | | COVERED LANAI (FF = -1.5 INCHES) IS CONSIDERED AN | | | ENCLOSED AREA BELOW THE FINISHED FLOOR AND SHOULD BE | | | ENTERED INTO LINE C2(A) OF THE ELEVATION CERTIFICATE AS | | | 8.455 FEET NAVD. (FF = 8.58 FT - .125 FT = 8.455 FT). | | | (CONVERSION - 1.5 INCHES = .125 FT) | | | | | | 3. SECTION C2(B)-ELEVATION SHOULD BE 8.58 FEET NAVD | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|