2021-03-26 14:19:09PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER PX3169 1&2 FAMILY - SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 RE: FLOOD OPENINGS: REFERENCE ELEVATION CERTIFICATE
 INSTRUCTIONS FOR SECTION A9 AND PERMIT 19080314, PLAN
 PAGES A3.0 AND A5
  
 1. SUBMIT REVISION TO PERMIT 19080314. LOCATE REQUIRED
 FLOOD OPENINGS IN ADJACENT WALL OR DOOR. (OHD)
  
 FBC R322.2.2.1INSTALLATION OF OPENINGS.
  
 THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS
 INSTALLED SUCH THAT:
 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON
 DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING
 HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD
 ELEVATION, EACH AREA SHALL HAVE OPENINGS.
 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN
 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR
 GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE
 IMMEDIATELY UNDER EACH OPENING.
 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN
 DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED
 OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION.
  
 FEMA TECHNICAL BULLETIN #1
  
 MINIMUM NUMBER OF OPENINGS
 EACH ENCLOSED AREA IS REQUIRED TO HAVE A MINIMUM OF TWO
 OPENINGS ON EXTERIOR WALLS TO ALLOW FLOODWATERS TO
 ENTER DIRECTLY. IN ORDER TO MEET THE REQUIREMENT, THE
 OPENINGS MUST BE LOCATED SO THAT THE PORTION OF THE
 OPENING INTENDED TO ALLOW FOR INFLOW AND OUTFLOW IS
 BELOW THE BFE. OPENINGS THAT ARE ENTIRELY ABOVE THE BFE
 (OR ANY PORTION OF AN OPENING THAT IS ABOVE THE BFE)
 WILL NOT SERVE THE INTENDED PURPOSE DURING BASE FLOOD
 CONDITIONS AND THUS ARE NOT COUNTED TOWARDS THE
 COMPLIANCE WITH THE FLOOD OPENING REQUIREMENTS.
 THE OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO SIDES
 OF EACH ENCLOSED AREA TO DECREASE THE CHANCES THAT ALL
 OPENINGS COULD BE BLOCKED WITH FLOATING DEBRIS AND TO
 ALLOW FOR MORE EVEN FILLING BY FLOODWATER AND DRAINING
 OF THE ENCLOSED AREA. IT IS RECOMMENDED THAT OPENINGS
 BE REASONABLY DISTRIBUTED AROUND THE PERIMETER OF THE
 ENCLOSED AREA UNLESS THERE IS CLEAR JUSTIFI-CATION FOR
 PUTTING ALL OPENINGS ON JUST ONE OR TWO SIDES (SUCH AS
 IN TOWNHOUSES OR BUILDINGS SET INTO SLOPING SITES).
  
 2. IF ENGINEERED FLOOD VENTS ARE INSTALLED IN OHD,
 PROVIDE FLORIDA PRODUCT APPROVAL FOR THAT TYPE OF VENT.
 SITE SPECIFIC ENGINERING REQUIRED FOR THE OHD.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  