2021-03-17 11:16:38RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21030646
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- PROVIDE SPECIFICATIONS CLEARLY SHOWING HOW COMPLYING
 WITH THE NEW 2020 CODE REQUIREMENT FOR ROOFING
 UNDERLAYMENT SEC. 1507.1.1.1 FBC-BUILDING.
  
 2- CONTRACTOR NEEDS TO UPLOAD TO PROJECTDOX THE
 COMPLETE FLORIDA PRODUCT APPROVAL FOR SHINGLES AND
 ROOFING UNDERLAYMENT. ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE WAS UPLOADED. NEED TO UPLOAD THE
 INSTALLATION INSTRUCTIONS ALSO.
 FAC 61G20.3.001.
  
 3- NEED TO SPECIFY THE MEAN ROOF HEIGHT OF THE BUILDING
 AS REQUIRED BY THE CITY POLICY FOR ALL ROOFING PERMITS.
 NOTE: THIS IS A THREE STORY BUILDING. TYPICALLY,
 SHINGLES MAY NOT BE ABLE TO BE INSTALLED WHERE THE MEAN
 ROOF HEIGHT EXCEEDS 33FT, EXCEPT WHEN THE PRODUCT
 APPROVAL ALLOWS IT. SEE RAS115.
  
 4- NEED TO SPECIFY THE ROOF PITCH AS REQUIRED BY THE
 CITY POLICY FOR ALL ROOFING PERMITS.
  