2021-04-05 14:57:04CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21030566 2300 PALM BEACH LAKES BLVD # 312
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
 A. PER WPB FBC 107.2.1 AND WPB FBC 107.3.5.1.3 PROVIDE
 PLANS SHOWING ANY OF THE FOLLOWING AS APPLICABLE:
  
 1. MINIMUM PLUMBING FACILITIES
 A) PROVIDE PLUMBING FIXTURES AND A FIXTURE SCHEDULE,
 COMPLY WITH THE OCCUPANCY REQUIREMENTS OF FBC PL 403.1,
 TABLE 403.1, 404.1 AND 410.
  
 2. FIXTURE REQUIREMENTS
 A) COMPLY WITH FBC PL CHAPTER 4
 B) SHOW COMPLIANCE WITH FBC ACC CHAPTERS 3 AND 6.
 PROVIDE PLAN AND ELEVATION DETAILS FOR REQUIRED
 ACCESSIBLE PLUMBING FIXTURES AND ACCESSORIES.
  
 3. WATER SUPPLY PIPING
 A) PROVIDE PLAN VIEW AND RISER DIAGRAM OF HOT AND COLD
 WATER; SHOW SIZING, VALVES, REQUIRED BACKFLOW
 PREVENTERS, WATER HAMMER ARRESTORS AND OTHER PLUMBING
 APPURTENANCES. INDICATE FIXTURES AND EQUIPMENT BEING
 SERVICED OR INCORPORATED INTO THE SYSTEM (IE. WATER
 HEATER, RECIRC PUMP, TRAP PRIMERS).
 B) SEE FBC PL E607.5 REGARDING INSULATION OF HOT WATER
 PIPING. COMPLY AS IS APPLICABLE.
 C) PROVIDE TABLES USED FOR CALCULATIONS FOR SIZING; SEE
 TO FBC PL CHAPTER 6 AND APPENDIX E.
  
 4. SANITARY DRAINAGE
 A) PROVIDE PLAN VIEW AND RISER DIAGRAM OF SANITARY
 DRAINS, WASTE AND VENTS; COMPLY WITH FBC PL CHAPTERS 7,
 8, 9 AND 10. INDICATE FIXTURES, ANY FLOOR DRAINS AND
 EQUIPMENT BEING SERVICED. SHOW SIZING. PROVIDE TRAP
 PRIMERS FOR FLOOR DRAINS AND PROVIDE DETAIL.
  
 5. WATER HEATERS
 A) SHOW WATER HEATER LOCATION
 B) PROVIDE SCHEDULE WITH MANUFACTURER, MODEL NUMBER,
 SIZE/CAPACITY, ELECTRICAL CHARACTERISTICS OR FUEL
 GAS/BTUS
 C) PROVIDE DETAIL WITH MANUFACTURER, MODEL NUMBER,
 SIZE/CAPACITY, ELECTRICAL CHARACTERISTICS OR FUEL
 GAS/BTUS, PIPING INCLUDING CW, HW, VALVES (INCLUDING
 VACUUM RELIEF VALVE IF APPLICABLE FBC PL 504.2) ,
 THERMAL EXPANSION CONTROL DEVICE (INCLUDING SIZE), T&P
 DISCHARGE (INCLUDING TERMINATION) AND WATER HEATER PAN
 AND DRAIN (INCLUDING TERMINATION) PER WPB FPC 107.2.1;
 COMPLY WITH FBC PL 607.3, 503.1, 504.1, 504.4, 504.4.1,
 504.5, 504.6, 504.7, 504.7.1 AND 504.7.2.
  
 6. VENTS
 A) SEE SANITARY DRAINAGE
  
 7. ROOF DRAINAGE
 A) IF APPLICABLE, COMPLY WITH FBC PL CHAPTER 11.
  
 8. BACKFLOW PREVENTION
 A) PROVIDE SCHEDULE AND SPECIFICATIONS
  
 9. IRRIGATION
 A) AS APPLICABLE
  
 10. LOCATION OF WATER SUPPLY LINE
 A) SHOW ON PLANS
  
 11. GREASE TRAPS
 A) IF APPLICABLE COMPLY WITH FBC PL CHAPTER 10. PROVIDE
 CALCULATIONS, TYPE AND DETAIL
  
 12. ENVIRONMENTAL REQUIREMENTS
 A) AS REQUIRED BY BUILDING DEPARTMENT
  
 13. PLUMBING RISER (SANITARY AND WATER)
 A) SEE COMMENTS IN WATER SUPPLY PIPING AND SANITARY
 DRAINAGE
  
 14. DESIGN FLOOD ELEVATION
 A) AS REQUIRED BY BUILDING DEPARTMENT
  
  
 END OF COMMENTS.
  
 A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT
 THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A
 RESPONSE NARRATIVE ADDRESSING THE GAS/PLUMBING COMMENTS
 FROM THE PRIOR REVIEW.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21030566 2300 PALM BEACH LAKES BLVD # 312