Date Text
2021-03-25 14:19:54** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE QUALITY OF THE PLAN IS VERY DIFFICULT TO READ.
 PLEASE SUBMIT A BETTER QUALITY PRINT OUT OF THE PLAN.
  
 2.) SHOW SETBACK DISTANCE FROM THE PROPOSED PAVERED
 WALKWAY/PATIO/DECK/TERRACE TO THE PROPERTY LINE. PLEASE
 NOTE THAT THE WALKWAY/PATIO/DECK/TERRACE CANNOT BE SET
 CLOSER THAN 2 FT. TO THE PROPERTY LINE. [ZLDR
 S.94-305(B)(7)]
  
 3.) DRIVEWAY IMPROVEMENT SHALL BE SETBACK AT LEAST 3
 FT. FROM THE SIDE PROPERTY LINE. [ZLDR S.94-482(D)]
  
 4.) HOW WIDE IS THE DRIVEWAY IMPROVEMENT? THE WIDTH OF
 THE DRIVEWAY CANNOT EXCEED 20 FT. AT THE PROPERTY LINE.
 PLEASE PROVIDE DIMENSIONS. [ZLDR S.94-312(C)]
  
 5.) THE PROPERTY IS REQUIRED TO MAINTAIN 1,000 SQ. FT.
 OR 75% OF LANDSCAPE AREA WITHIN THE REQUIRED FRONT YARD
 (THE AREA WITHIN THE FIRST 25 FT. OF THE FRONT PROPERTY
 LINE). PLEASE PROVIDE CALCULATIONS TO SHOW THAT THE
 LANDSCAPE REQUIREMENT BE MAINTAINED WITH THE PROPOSED
 IMPROVEMENTS.
  
 6.) SHOW SETBACK DISTANCE OF THE PROPOSED 6 FT. TALL
 FENCE/GATE FROM THE FRONT, SIDE AND REAR PROPERTY
 LINES. PLEASE NOTE THAT A 6 FT. HIGH FENCE/GATE IS NOT
 PERMITTED WITHIN THE FIRST 25 FT. OF THE FRONT PROPERTY
 LINE. [ZLDR S.94-302(B)]
  
  
 NOTES:
  
 * SEPARATE PERMIT REQUIRED FOR THE PROPOSED 6 FT. TALL
 PVC FENCE AND GATE.
  
 * VALUE OF THE SCOPE OF WORK DOES NOT TRIGGER LANDSCAPE
 REQUIREMENT.
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: SF7
  


Account Summary | Usage Policy | Privacy Policy