| 2022-02-15 16:09:09 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT- 21030413 |
| | 2/15/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET P2.1: THE PLAN MAKES NUMEROUS REFERENCES TO |
| | CIVIL DRAWINGS WHICH ARE NOT INCLUDED IN THE SET. |
| | PLEASE PROVIDE THE DRAWINGS OR PROVIDE THE FOLLOWING |
| | INFORMATION ON THE PLAN: |
| | A) LABEL THE SANITARY SEWER LINES CORRECTLY AND |
| | INDICATE THE PIPE SIZES- SEC. 701.2 FBC P. |
| | B) LOCATIONS OF CLEANOUTS FOR THE SANITARY SEWER LINE |
| | AND AT THE GREASE INTERCEPTOR- SECS. 708.1.2 & 1003.3.5 |
| | FBC P. |
| | C) LOCATION OF GREASE INTERCEPTOR SAMPLING PORT- SEC. |
| | 1003.3.5 FBC P. |
| | |
| | 2) SHEET P2.1: THE GREASE INTERCEPTOR SHALL NOT BE |
| | INSTALLED UNDER THIS PERMIT AND SHALL BE LABELED AS |
| | FUTURE, FOR REFERENCE ONLY. A SEPARATE PERMIT IS |
| | REQUIRED AND A NOTE SHALL BE PLACED ON THE PLAN TO |
| | CLARIFY. COMPLETE GREASE WASTE PIPING PLANS, |
| | SPECIFICATIONS, SIZING CALCULATIONS ETC. ARE REQUIRED |
| | UNDER THE RESTAURANT BUILDOUT AND THE SEPARATE GREASE |
| | INTERCEPTOR PERMIT- SEC. 107.2.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |