| Date |
Text |
| 2021-03-25 07:56:10 | 1ST REVIEW FBC-2020 FUEL GAS |
| | PERMIT- 21030271 |
| | 3/25/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THE IS APPEARS TO BE A NEW INSTALLATION AND NOT A |
| | LIKE FOR LIKE REPLACEMENT. PLEASE PROVIDE A PLAN |
| | SHOWING THE LOCATION OF THE NEW WATER HEATER AND A GAS |
| | RISER DRAWING- SECTIONS 107.3.5.3.1 AND 107.2.1 WPB. |
| | PLEASE SHOW ALL REQUIRED INSTALLATION CLEARANCE |
| | DISTANCE MEASUREMENTS ON THE PLAN PER MANUFACTURER'S |
| | SPECIFICATIONS, AND SUBMIT A COMPLETE SPEC SHEET THAT |
| | SHOWS THE BTU LOAD AND INPUT PRESSURE- SECTION 624.1 |
| | FBC FG. |
| | |
| | 2) THE GAS RISER SHALL BE A COMPLETE GAS RISER FOR THE |
| | RESIDENCE THAT INCLUDES ALL NEW AND EXISTING GAS PIPING |
| | AND APPLIANCES AND EQUIPMENT- SECTIONS 401.3 & 401.4 |
| | FBC FG. PLEASE PROVIDE: |
| | |
| | A) TYPE OF GAS- NATURAL OR LP. |
| | B) DELIVERY PRESSURE AT THE METER. |
| | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. |
| | D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | F) TYPES AND SIZES OF PIPING. |
| | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE |
| | UNIONS. |
| | H) OUTLET PRESSURES AT REGULATORS. |
| | I) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| | |
| | 3) PERMIT VALUE SHALL INCLUDE THE COST OF THE NEW WATER |
| | HEATER- SECTION 109.3 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | CCOLE@WPB |
| | |