Plan Review Notes
Plan Review Notes For Permit 21030139
Permit Number 21030139
Review Stop P
Sequence Number 2
Notes
Date Text
2021-05-13 13:34:24CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 NFPA 99 = HEALTH CARE FACILITIES CODE
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW
  
 PLUMBING COMMENTS: DENIED
  
 NEW COMMENTS: REGARDING CONDENSATE DISCHARGE TO THE
 EXISTING FLOOR DRAIN AND ELIMINATION OF TRIPPING
 HAZARD.
  
 1.IT IS BROUGHT TO MY ATTENTION THAT PER WPB CODE OF
 ORDINANCE CHAPTER 90, ARTICLE 3, SECTION 90-12B5, A/C
 CONDENSATE SHALL NOT DISCHARGE TO THE CITY UTILITIES
 SANITARY SEWAGE INFRASTRUCTURE WITHOUT PERMISSION FROM
 THE UTILITIES DEPARTMENT. YOU MAY CONTACT MR. MANNY
 GONZALES IN ENGINEERING AT 561-494-1128 FOR ADDITIONAL
 INFORMATION. MOVING FORWARD, DISCHARGE THE CONDENSATE
 TO AN EXTERIOR DRYWELL; PER WPB FBC 107.2.1, PROVIDE
 ROUTING AND DRYWELL DETAIL.
  
 2. DUE TO THE RAISED FLOOR, PLEASE NOTE THAT PER FBC PL
 413.2, READY ACCESS SHALL BE PROVIDED TO FLOOR DRAINS.
 READY ACCESS IS DEFINED IN FBC PL CHAPTER 2,
 DEFINITIONS AS THAT WHICH ENABLES A FIXTURE, APPLIANCE
 OR EQUIPMENT TO BE DIRECTLY REACHED WITHOUT REQUIRING
 THE REMOVAL OR MOVEMENT OF ANY PANEL, DOOR OR SIMILAR
 OBSTRUCTION AND WITHOUT THE USE OF A PORTABLE LADDER,
 STEP STOOL OR SIMILAR DEVICE.
  
  
 END OF COMMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND
 FS.END OF COMMENTS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21030139 901 45TH ST


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved