Plan Review Notes
Plan Review Notes For Permit 21021211
Permit Number 21021211
Review Stop B
Sequence Number 4
Notes
Date Text
2021-05-24 15:06:39BUILDING PROVISO: INSPECTOR AT JOBSITE TO VERIFY A
 PARKING GARAGE IS DIRECTLY BENEATH THIS UNI IF A
 PARKING GARAGE DOES EXIST THEN NO SOUND INSULATION WAS
 REQUIRED. UNDER THE SCOPE OF WORK THE HEADING OF
 LIMITATION OF TILE INSTALLATION THE ENTIRE CONDOMINIUM
 UNIT HAS NEW WOOD FLOORING ON TOP OF EXISTING TILE
 FLOORING. I HAVE RESEARCHED THE ADDRESS OF 3930 N
 FLAGLER DR. AND FOUND NO PERMITS FOR THE INSTALLATION
 OF WOOD FLOORING FOR THIS UNIT. 2020 EXISTING BUILDING
 CODE LEVEL II 801.3 COMPLIANCE. ALL NEW CONSTRUCTION
 ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,
 BUILDING. CREATION OR EXTENSION OF NONCONFORMITY. ALL
 NEW WORK, RE-CONFIGURATION SHALL NOT CREATE OR EXTEND
 ANY NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE
 RE-CONFIGURATION OF SPACE IS BEING MADE WITH REGARD TO
 ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS, OR THE CAPACITY OF MECHANICAL, PLUMBING, OR
 ELECTRICAL SYSTEMS.J. WITMER BUILD. PLANS EXAMINER.
 5/24/2021