| 2021-03-12 08:28:40 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE SITE PLAN NEEDS TO SHOW THE DISTANCES TO THE |
| | PROPERTY LINES AND DISTANCE FROM THE OTHER BUILDINGS ON |
| | THE PROPERTY. FBC 107.2.5 |
| | |
| | 2) FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING |
| | PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, |
| | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO |
| | RECORDS MANAGEMENT. |
| | |
| | 3) UNLESS THE PLANS ARE PREPARED BY A FLORIDA LICENSED |
| | ARCHITECT OR ENGINEER THEY ARE REQUIRED TO BE DESIGNED |
| | IN ACCORDANCE WITH AN APPROVED PRE-SCRIPTIVE METHOD OR |
| | THE FBC RESIDENTIAL. THE PROPOSED FOUNDATION TYPE IS |
| | NOT ALLOWED WITHOUT ENGINEERING. FBC 301 |
| | |
| | 4) THE FBC REQUIRES A DOUBLE FLOOR SILL BEAM AROUND THE |
| | EXTERIOR TO SUPPORT THE WALLS AND CARRY THE FLOOR JOIST |
| | LOADS. THERE ARE OTHER ISSUES WITH THIS DESIGN THAT |
| | WILL NEED TO BE ADDRESSED. FBC R502 |
| | |
| | 5) IDENTIFY THE SPECIFIC HURRICANE CLIPS AND ANCHORS |
| | THAT WILL BE USED. FBC 107.2.1 & FBC-R 301.1 |
| | |
| | 6) SPECIFY THE SPECIFIC EXTERIOR PLYWOOD THAT WILL BE |
| | USED. FBC 107.2.1 |
| | |
| | 7) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIALS, |
| | DOORS AND WINDOWS. FBC 107.3.4 - PROVIDE TWO SETS OF |
| | PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE |
| | REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE |
| | 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE |
| | PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING |
| | INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES |
| | FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW |
| | (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR |
| | TYPES. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR |
| | ELECTRONICALLY SUBMITTED DOCUMENTS. |
| | |
| | 8) THIS IS A LINK TO A SHED DESIGN THAT YOU CAN USE AS |
| | A GUIDE FOR YOUR SHED. HTTPS://WWW.JUPITER.FL.US/DOCUME |
| | NTCENTER/VIEW/6511/SITE-BUILT-SHED-BCAB?BIDID= |