| 2021-03-15 10:36:56 | 1ST REVIEW FBC-2020 RES. |
| | PERMIT- 210200978 |
| | 3/15/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET 4, PLUMBING RISER: SHOW A 2 IN. STANDPIPE AND |
| | 3 IN. VERTICAL FIXTURE BRANCH FOR THE WASHING MACHINE- |
| | SECTION 406.2 FBC P. |
| | |
| | 2) SHEET 4: PROVIDE A SCOPE OF WORK FOR PLUMBING |
| | ALTERATIONS- SECTION 107.2.1 WPB. PROVIDE A LIST OF |
| | FIXTURES BEING REPLACED OR INSTALLED AS NEW. |
| | |
| | 3) SHEET 4: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW |
| | TANKLESS WATER HEATER AND SUBMIT MANUFACTURER'S |
| | SPECIFICATIONS- SECTIONS P2801.3 & G2448 FBC RES. |
| | |
| | 4) SHEET 4: INDICATE TYPE OF BATHTUB VALVES TO BE |
| | INSTALLED- SEE SECTIONS P2708.4 & P713.3 FBC-RES. |
| | |
| | 5) SUBMIT A PLUMBING SUB-PERMIT APPLICATION- SECTION |
| | 105.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |