| 2021-04-26 18:03:54 | FAILED | | | | | | 1ST FLOOR FASCIA IDENTITY SIGN | | | | | | 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE | | | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF | | | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES. | | | WHILE THIS IS NOTED ON SHEET A1, IT IS NOT UPDATED ON | | | SHEET A3, WHICH IS SIGNED BY THE ENGINEER. SHEET A3 | | | STILL SHOWS THE ALUMINUM RETURNS AS ONLY HAVING A | | | THICKNESS OF .050 INCHES. | | | | | | 2) PROVIDE HOW THE SHIELDED LED CABLE CONDUITS TO THE | | | REMOTE LED DRIVER ASSEMBLY LOCATED INSIDE THE STORE | | | WILL BE CONCEALED AND NOT VISIBLE TO THE PUBLIC AS THEY | | | CROSS THE ARCADE AS REQUIRED BY THE ROSEMARY SQUARE | | | TENANT SIGN CRITERIA. THIS INCLUDES ANY BELL BOX, J BOX | | | OR OTHER ELECTRICAL CONNECTION. IF THE CONDUIT, ETC. IS | | | IN THE ARCADE CEILING YOU MAY PROVIDE THIS INFORMATION | | | AS A NOTE ON THE PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | |
|