| 2021-03-19 15:34:40 | PLAN REVIEW / ROOFING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER PX3169 / 1&2 FAMILY SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 2ND REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED. |
| | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| | PREVIOUS |
| | |
| | |
| | NOTICE: SITE SPECIFIC DESIGN WIND LOADS PER FBC R301 |
| | TABLE R301.2(2) (-89.4PSF) AND TABLE R301.2(3) |
| | (ADJUSTMENT COEFFICIENT OF 1.21 ARE -108.17PSF |
| | PRODUCT APPROVAL FL16717-R10 PROVIDES A MDP OF -60.0PSF |
| | (SYSTEM W-124 SELECTED) |
| | |
| | 1. PROVIDE ENHANCED FASTENER CALCULATIONS FOR ZONES 2 |
| | AND 3 PREPARED BY A DESIGN PROFESSIONAL. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | NEW COMMENTS: |
| | |
| | 1. SYSTEMS W-122, W-126 AND W-129 WOULD GIVE YOU A |
| | DESIGN PRESSURE OF -112.5 AND WOULD BE APPROVED FOR |
| | INSTALLATION. |
| | |
| | 2. PRODUCT APPROVAL 17442-R5 (LIQUID APPLIED ROOF |
| | SYSTEMS), WAS SUBMITTED FOR REVIEW. SYSTEM C-17 IS |
| | SELECTED TO BE INSTALLED. THIS SYSTEM IS FOR CONCRETE |
| | DECKS. |
| | ARE YOU PROPOSING A CHANGE IN THE SCOPE OF WORK? IF SO, |
| | PROVIDE A CHANGE ORDER, SIGNED BY OWNER. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | PROVIDE CLARIFICATION. |