| 2021-06-22 17:11:37 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1 |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 |
| | 6TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 21020368 360 S ROSEMARY AVE |
| | 2ND REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | |
| | REFER TO RED LINED PLANS P0.01 AND P903.1 |
| | |
| | 1. PROVIDE ON P0.01, A NOTE STATING ?PROVIDE LEAD FREE |
| | PRESSURE REDUCING VALVES WITH STRAINERS ON ALL SERVICE |
| | OUTLETS ON THE DISCHARGE SIDE OF THE DOMESTIC BOOSTER |
| | PUMPS COMPLYING WITH THE 2017 FLORIDA PLUMBING CODE?. |
| | (COMPLIED ON P9.01 AND P9.04. |
| | |
| | 2. P9.03: SANITARY RISER SAN 1; NOTE, 903.1 HAS BEEN |
| | REVISED BUT STILL DOES NOT ACCURATELY DESCRIBE WHAT IS |
| | HAPPENING. |
| | A) VENT STACK SHALL CONNECT VERTICALLY TO THE |
| | HORIZONTAL DRAIN PER FBC PL 905.3 AND 905.4. |
| | B) SHOW AT TOP OF RISER WHERE CONNECTED TO THE |
| | HORIZONTAL BRANCH THAT THE WASTE STACK AND VENT STACK |
| | CONTINUE VERTICALLY TO SERVICE THE TYPICAL RESTROOMS |
| | ABOVE. REFERENCE P9.01 AND SIZE THE STACKS. |
| | C)CONFIRM AND INDICATE FLOOR LEVELS WHERE NOTED. |
| | D)ADDITIONAL CLARIFICATIONS NEEDED: SEE P4.08A FOR 6" |
| | HORIZONTAL BRANCH WITH LATERALS TO STACKS FOR FUTURE. |
| | SEE P4.09A SHOWING STACKS SAN 1A, 1B, 1C AND 1D. SEE |
| | P9.01 SANITARY RISER FOR SEPARATE STACKS. RECONCILE |
| | PLEASE. |
| | |
| | |
| | END OF COMMENTS. |
| | A COMPREHENSIVE REVIEW COULD NOT BE ACCOMPLISHED AT |
| | THIS TIME. PLEASE RESUBMIT CLEARLY LEGIBLE PLANS AND A |
| | RESPONSE NARRATIVE ADDRESSING THE PLUMBING COMMENTS |
| | FROM THE FIRST REVIEW. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | MOBILE 561-243-0882 |
| | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND |
| | THURSDAYS |
| | |
| | 21020368 360 S ROSEMARY AVE |
| | |