| Plan Review Notes For Permit 21020360 |
| Permit Number |
21020360 |
|
| Review Stop |
E |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2021-06-15 13:54:16 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | WORK SURFACE COUNTER TOP IN LAUNDRY ROOM REQUIRES | | | OUTLETS PER 210.52(C)(1) | | | | | | 210.52(C)(1) WALL COUNTERTOP AND WORK SURFACE. A | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL | | | COUNTERTOP AND WORK SURFACE THAT IS 300 MM (12 IN.) OR | | | WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO | | | POINT ALONG THE WALL LINE IS MORE THAN 600 MM (24 IN.) | | | MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT | | | SPACE. |
|