| 2021-05-20 08:24:30 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROPOSED STORE FRONTS AND DOOR WILL ENCLOSE THE | | | OPEN SIDE OF THE EXTERIOR EXIT STAIRS AND SIGNIFICANTLY | | | INCREASE THE ACCUMULATION OF SMOKE OR TOXIC GASES IN | | | THE STAIRWAY. ON THE GROUND FLOOR OF THE EXIT STAIRS | | | THERE IS A WALL AND A DOOR AT THE INTERIOR CORRIDOR. | | | THE STAIR AT THIS FLOOR WOULD BE TOTALLY ENCLOSED. IF | | | THE EXTERIOR WALL OF THE EXTERIOR EXIT STAIRWAY IS | | | ENCLOSED THE STAIRWAY WOULD BE CONSIDERED AN INTERIOR | | | STAIRWAY AND WOULD BE REQUIRED TO COMPLY WITH FBC 1023. | | | SEE FBC 1027. | | | | | | 2) THERE ARE TWENTY-SIX (26) PLAN SHEETS IN THE | | | SIGNATURE FILE AND TWENTY-FIVE (25) PLAN SHEETS IN THE | | | DRAWINGS FILE. THERE ARE TWO PLANS FOR 088-A-3.1.1 IN | | | THE SIGNATURE FILE. ONE ELEVATION SHOWS A GATE AT THE | | | ARCADE ENTRANCE AND THE OTHER SHOWS STOREFRONTS. PLEASE | | | CLARIFY. FBC 107.2.1 |
|