2021-05-20 08:24:30PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PROPOSED STORE FRONTS AND DOOR WILL ENCLOSE THE
 OPEN SIDE OF THE EXTERIOR EXIT STAIRS AND SIGNIFICANTLY
 INCREASE THE ACCUMULATION OF SMOKE OR TOXIC GASES IN
 THE STAIRWAY. ON THE GROUND FLOOR OF THE EXIT STAIRS
 THERE IS A WALL AND A DOOR AT THE INTERIOR CORRIDOR.
 THE STAIR AT THIS FLOOR WOULD BE TOTALLY ENCLOSED. IF
 THE EXTERIOR WALL OF THE EXTERIOR EXIT STAIRWAY IS
 ENCLOSED THE STAIRWAY WOULD BE CONSIDERED AN INTERIOR
 STAIRWAY AND WOULD BE REQUIRED TO COMPLY WITH FBC 1023.
 SEE FBC 1027.
  
 2) THERE ARE TWENTY-SIX (26) PLAN SHEETS IN THE
 SIGNATURE FILE AND TWENTY-FIVE (25) PLAN SHEETS IN THE
 DRAWINGS FILE. THERE ARE TWO PLANS FOR 088-A-3.1.1 IN
 THE SIGNATURE FILE. ONE ELEVATION SHOWS A GATE AT THE
 ARCADE ENTRANCE AND THE OTHER SHOWS STOREFRONTS. PLEASE
 CLARIFY. FBC 107.2.1