2021-09-04 08:59:40BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/RPX306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 SOW: INSTALL NON-IMPACT RATED WINDOWS. SHUTTER PANEL
 PRODUCT APPROVAL AND SHUTTER SCHEDULE SUBMITTED FOR
 REVIEW.
  
 1. STORM PANEL NOA NO. 17-0925.04 AND PRODUCT APPROVAL
 FL 11968-R5 HAVE BEEN SUBMITTED FOR REVIEW.
 TWO PRODUCT COMPLIANCE REPORTS ARE NOT REQUIRED. REMOVE
 EITHER THE NOA OR PRODUCT APPROVAL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. DESIGNER SHALL HIGHLIGHT CONNECTION TYPE, ANCHOR
 TYPE AND SPACING ON STORM PANEL NOA OR PRODUCT
 APPROVAL.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
  
 REF. SHUTTER SCHEDULE FOR THE FOLLOWING COMMENTS:
  
 3. PRODUCT COMPLIANCE REPORTS ARE INDICATED AS FL419
 AND NOA NO. 15-07142.22. THESE REPORTS HAVE NOT BEEN
 SUBMITTED FOR REVIEW.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 4. WALL PRESSURE DATA IS MISSING.
 5. SHUTTER MOUNTING CONNECTION TYPE IS INDICATED AS
 ANCHOR BOLOTS. DESIGNER SHALL HIGHLIGHT THE CONNECTION
 TYPE FROM THE SELECTED AND REVIEWED PRODUCT APPROVAL.
 6. SHUTTER GLASS SEPERATION INDICATED AS 4". DESIGNER
 SHALL HIGHLIGHT THIS ON PRODUCT APPROVAL.
 7. SHUTTER SPANS ARE LESS THAN SHUTTER HEIGHT. SHUTTERS
 ARE INSTALLED VERTICALLY. SHUTTER SPAN CANNOT BE LESS
 THAN SHUTTER HEIGHT PLUS ANCHOR BOLT EDGE DISTANCE.
 8. MINIMUM EDGE DISTANCE. DESIGNER SHALL HIGHLIGHT
 THESE ON PRODUCT APPROVAL.
 9. ANCHOR SPACING. DESIGNER SHALL HIGHLIGHT THESE ON
 PRODUCT APPROVAL.
 10. ANCHOR TYPE IS INDICATED AS PANEL MATE. ANCHORS
 SHALL BE SPECIFIC PER NOTE # 1 ON SHUTTER SCHEDULE.
 DESIGNER SHALL HIGHLIGHT THESE ON PRODUCT APPROVAL.
 11. CENTER BOLTS OR RE-INFORCING. ENTER EITHER YES OR
 NO AND HIGHLIGHT ON PRODUCT APPROVAL.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 12. INCREASE VALUE BASED ON THE ADDITIONAL SOW. (STORM
 PANELS)
 CITY OF WPB CHPT109.3 BUILDING PERMIT VALUATIONS.
  
 1A. VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF WORK.
 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR,
 MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE
 OF WORK.
 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY
 THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  


Account Summary | Usage Policy | Privacy Policy