Plan Review Notes
Plan Review Notes For Permit 21020115
Permit Number 21020115
Review Stop B
Sequence Number 2
Notes
Date Text
2021-06-02 08:59:21WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21020115
 ADD: 1316 ALAPHA STREET, UNIT # 1
 CONT: GEN-X CONSTRUCTION, INC.
 TEL: 561-963-4490
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JUNE 02ND / 2021
 ACTION: DENIED
 1) SHEET 1ST FLOOR PLAN.
 1A) WHEN VIEWING THE FRONT ENTRY TO UNIT # 3 THROUGH MY
 GEO NAV THE FRONT ENTRY DOORWAY APPEARS TO BE BETWEEN A
 1 ? INCHES TO 1 INCH ABOVE THE SIDEWALK. FAIR HOUSING
 GUIDELINES SECTION 5 (1)(A) SEPARATE GROUND FLOOR
 ENTRANCES. WHEN A GROUND FLOOR UNIT OF A BUILDING HAS A
 SEPARATE ENTRANCE, EACH GROUND FLOOR UNIT SHALL BE
 SERVED BY AN ACCESSIBLE ROUTE. SEE SECTION (B) WHERE
 MULTIPLE DWELLING UNITS ARE ON THE 1ST FLOOR MORE THAN
 ONE MANY MAYBE REQUIRED TO BE ACCESSIBLE.
 1ST ROUND OF COMMENTS. THE 1ST FLOOR PLAN INDICATES A
 NEW RAMP AT THE EXTERIOR SIDE OF THE FRONT DOOR. THE
 PLANS DO NOT CLEARLY SHOW THE TOP AND BOTTOM LANDINGS.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-BUILDING
 SECTION 1012.6 LANDINGS. RAMPS SHALL HAVE LANDINGS AT
 THE BOTTOM AND TOP OF EACH RAMP, POINTS OF TURNING
 ENTRANCE, EXITS AT DOORS AND IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE ACCESSIBILITY. LANDINGS SHALL
 COMPLY WITH SECTION 1012.6.1 THROUGH 1012.6.5.
  
 1B) 2ND REQUEST. DOORWAYS AT RAMPS (LANDINGS). 1012.6,5
 OF THE 2020 FBC-BUILDING. FAIR HOUSING ANSI A117.1
 SECTION 4.8. WHERE DOORWAYS ARE LOCATED ADJACENT TO A
 RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC
 A117.1 ARE PERMITTED TO OVERLAP THE REQUIRED LANDING
 AREA.
  
 1C) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 SHEET 1ST FLOOR PLAN AT FRONT ENTRY INDICATES THE
 BUILDING OF A NEW RAMP. THERE ARE SOME DIMENSIONS BUT
 THERE IS NO MENTION OR DETAILS FOR BUILDING THE LANDING
 NOR RAMP SECTION ITSELF. PLEASE SHOW COMPLIANCE WITH
 SECTION 1012.7 RAMP CONSTRUCTION. THE PLANS ARE SILENT
 AS TO THE LIVE LOAD DISTRIBUTIONS SEE FBC-B TABLE
 1607.1.
  
 1D) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.1. RAMP SURFACE. THE SURFACE OF RAMPS SHALL BE
 OF A SLIP-RESISTANT MATERIALS THAT ARE SECURELY
 ATTACHED.
  
 1E) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 PLEASE SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 1012.7.2. OUTDOOR CONDITIONS. OUTDOOR RAMPS AND OUTDOOR
 APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER
 WILL NOT ACCUMULATE ON THE WALKING SURFACES.
  
 1G) 2ND REQUEST. FAIR HOUSING ANSI A117.1 SECTION 4.8.
 THIS PROPOSED RAMP IS INDICATED TO BE 1 ? INCHES IN
 HEIGHT. HANDRAILS REQUIRED BY 1012.8 ARE NOT REQUIRED
 FOR RAMPS LESS THAN 6 INCHES. GUARDS REQUIRED BY 1012.9
 WHERE REQUIRED BY 1015.2 RAMPS AND LANDINGS LOCATED 30
 INCHES ABOVE GRADE, ALSO NOT REQUIRED. EDGE PROTECTION
 REQUIRED BY SECTION 1012.10 IS NOT INDICATED ON THE
 PLANS.
  
 1H-K) N/A, NOT APPLICABLE.
  
 1L) BATHROOM GRAB BARS FOR THE WATER CLOSET. 2021
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  
  
  