Plan Review Notes
Plan Review Notes For Permit 21011181
Permit Number 21011181
Review Stop B
Sequence Number 2
Notes
Date Text
2021-04-09 10:03:10SFR ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) SYSTEM TYPE (E2) - ROOFING SYSTEM TO BE USED ON THE
 PROVIDED PRODUCT APPROVAL (20-0131.01) REQUIRES
 ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH
 REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE
 PRODUCT APPROVAL (-52) - SEE GENERAL LIMITATION NOTE
 NUMBER 7 ON THE PRODUCT APPROVAL. SEE ROOF CLADDING
 PRESSURES ON DRAWING S-100
 2) PRODUCT APPROVAL FOR THE ROOFING SHINGLES NEEDS TO
 BE THE UPDATED VERSION (FL10674-R16) YOU PROVIDED (FL
 10674-R8)
 3) YOU CANNOT RELOCATE A DOOR OR WINDOW WITHOUT AN
 UPDATED PRODUCT APPROVAL FBC EXISTING BUILDING 707.4
 REPLACEMENT OF WINDOWS AND DOORS.
 THE REPLACEMENT OF GARAGE DOORS, EXTERIOR DOORS,
 SKYLIGHTS, AND OPERATIVE AND INOPERATIVE WINDOWS SHALL
 BE DESIGNED AND CONSTRUCTED TO COMPLY WITH CHAPTER 16
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 YOU CAN HAVE A DESIGNED CUSTOM DOOR THAT MEETS THE
 REQUIRED WIND LOADS - FBC R609.2.1 CUSTOM DOORS.
 CUSTOM (ONE-OF-A-KIND) EXTERIOR DOOR ASSEMBLIES SHALL
 BE TESTED BY AN APPROVED TESTING LABORATORY OR BE
 DESIGNED AND ENGINEERED IN ACCORDANCE WITH ACCEPTED
 ENGINEERING PRACTICES BY A FLORIDA REGISTERED DESIGN
 PROFESSIONAL. SIGNED AND SEALED COPIES OF THE RATIONAL
 ANALYSIS AND CALCULATIONS SHALL BE PROVIDED TO THE
 BUILDING OFFICIAL UPON PERMIT APPLICATION. - (WOULD
 NEED SIGNED AND SEALED ATTACHMENT DETAILS FROM THE
 ARCHITECT OR ENGINEER).
  
 A SHUTTER WOULD BE REQUIRED TO PROTECT THE GLAZING OF A
 CUSTOM DESIGNED DOOR - FBC R301.2.1.2 PROTECTION OF
 OPENINGS.
 EXTERIOR GLAZED OPENINGS IN BUILDINGS LOCATED IN
 WINDBORNE DEBRIS REGIONS SHALL BE PROTECTED FROM
 WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR
 WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE
 LARGE MISSILE TEST OF ASTM E1996 AND ASTM E1886 AS
 MODIFIED IN SECTION 301.2.1.2.1, TAS 201, 202 AND 203,
 OR AAMA 506, AS APPLICABLE. ( COMPLETE MIAMI DADE OR
 FLORIDA STATE PRODUCT APPROVAL WOULD BE REQUIRED)