| Plan Review Notes For Permit 21010852 |
| Permit Number |
21010852 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-01-25 09:53:32 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2: | | | | | | 1) ELEVATIONS (INCLUDING THE GENERATOR PAD & EXTERIOR | | | MECHANICAL EQUIPMENT) NEED TO BE SHOWN ON THE SURVEY AT | | | LOCATIONS THAT MATCH SECTION C2 A-H (PAGE 2 OF 6) OF | | | THE ELEVATION CERTIFICATE. | | | 2) THE GENERATOR PAD NEEDS TO BE ADDED TO THE ELEVATION | | | CERTIFICATE SECTION D COMMENTS IN ADDITION TO THE | | | EXTERIOR A/C UNIT FOR LOWEST EQUIPMENT ELEVATION (PAGE | | | 2 OF 6). |
|