2021-02-03 10:44:05WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21010826
 ADD: 525 OKEECHOBEE BLVD. SUITE # ??? SPEC SUITE 840???
 CONT: HOLT LEE CONSTRUCTION
 TEL: 954-725-4881
 E-MAIL: GLEE@ HOLT-LEE, COM
  
 2020 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. FEB. 01/2021
 ACTION: DENIED
  
 1) PLEASE REVIEW THE ADDRESSING PLAN REVIEW COMMENT OF
 NEWLY DEVELOPED SUITE NUMBER. PERMIT # 21010826 WAS ONE
 SHELL TENANT SPACE, NOW IT IS SUB-DIVIDED. NEW TENANT
 ADDRESS HAS TO BE APPROVED BY WEST PALM BEACH
 ADDRESSING. 2020 FLORIDA BUILDING CODE W 2017 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED.
  
 2) COMMENTS FROM PERMIT 21010825 NEED TO BE ADDRESSED,
 THE SUB-DIVIDING OF THE LARGER SPACE STILL NEEDS TO BE
 ADDRESSED. WORK BEING COMPLETED UNDER THIS PERMIT
 21010826) CAN NOT CREATE A NON-CONFORMITY FOR THE WORK
 BEING COMPLETED UNDER THE PERMIT (21010825). OCCUPANT
 LOADS FOR BOTH TENANT SPACES NEED TO BE SHOWN ON THIS
 PERMIT AND TRAVEL DISTANCE FROM THE MOST REMOTE POINT
 IN THE PROPOSED SUITE FOR EACH TENANT.
 FBC-B SECTION 1010.1.2.1 DIRECTION OF SWING. PIVOTING
 OR SIDE HINGED SWING DOOR SHALL SWING IN THE DIRECTION
 OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA
 CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS.
  
 3) THE COVERSHEET LIST THE SQUARE FOOTAGE FOR THIS
 TENANT SPACE AS 3,064 SQ. FT./ AND 30 OCCUPANTS. PLEASE
 REVIEW CHANGES TO THE 2020 FBC-B OCCUPANT LOAD FACTOR
 FOR BUSINESS OCCUPANCIES, SEE TABLE 1004.5. THE NEW
 OCCUPANT LOAD FACTOR FOR A BUSINESS OCCUPANCY IS 150
 GROSS. 3064/150= 20.4 OR 21 OCCUPANTS. THE FLOOR PLAN
 SHOWS 42 SEATS. WITH THE COMMENTS FROM PERMIT 21010825
 BEING ANSWERED, WE DO NOT KNOW IF SPLITTING THE SHELL
 SPACE IN HALF DOES CREATE A NON-CONFORMITY.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved