| Date |
Text |
| 2021-03-02 11:51:21 | 2ND REVIEW FBC-2020 RES. PLUMBING |
| | PERMIT- 21010769 |
| | 3/2/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) SHEET A1: BASED ON THE NEW SUBMITTED SPECS FOR THE |
| | REFRIGERATOR, INDICATE HOW WATER WILL BE SUPPLIED TO |
| | THE UNIT. PLEASE NOTE THAT THE SHUTOFF VALVE FOR THE |
| | WATER SUPPLY SHALL BE IN A LOCATION WITH ACCESS- |
| | SECTION 107.3.5.3 WPB AND P2903.9.3 FBC RES. |
| | |
| | 2) A1: IT IS ACKNOWLEDGED THAT THE SINK PLUMBING WAS |
| | APPROVED UNDER PERMITS 02060575 & 02060590, HOWEVER THE |
| | NEW SINK INSTALLATION AND WATER SUPPLY LINE TO THE |
| | REFRIGERATOR WILL REQUIRED A PLUMBING SUB-PERMIT- |
| | SECTION 105.1 WPB. |
| | |
| | 3) A1: PROVIDE A WATER HAMMER ARRESTOR AND BACKFLOW |
| | PREVENTER FOR THE WATER LINE TO THE RERFRIGERATOR- |
| | SECTIONS P2902.3 & P2903.5 FBC RES. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |