| Date |
Text |
| 2021-03-02 11:48:19 | 2ND REVIEW FBC-2020 RES. FUEL GAS |
| | PERMIT- 21010769 |
| | 3/2/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC M- FLORIDA MECHANICAL CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | FAILED 1ST REVIEW COMMENTS ARE LISTED BELOW WITH |
| | ADDITIONAL NOTES FOR FURTHER CLARIFICATION. |
| | |
| | 1) FAILED. SHEET A1 NOTES 4 & 7: PROVIDE A GAS PIPING |
| | PLAN AND RISER DRAWING FOR INSTALLATION OF THE NEW GAS |
| | GRILL- SECTION 107.3.5.3 WPB. SHEET A1 SHOWS A GAS LINE |
| | CONNECTION "BY OTHERS" PLEASE REFER TO SECTION G2412.4 |
| | FBC RES AND PROVIDE A COMPLETE GAS ISOMETRIC DRAWING. |
| | PLEASE NOTE THAT THE ORIGINAL ISO FOR THE HOUSE UNDER |
| | PERMIT 02091557 SHOWED A FUTURE 45,000 BTU GRILL. THE |
| | NEW GRILL IS 89,000 BTU. |
| | |
| | 2) FAILED. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| | NEW GRILL INDICATING BTUH LOAD AND INPUT PRESSURE- |
| | SECTION G2447.1 FBC RES. PLEASE SHOW REQUIRED GRILL |
| | INSTALLATION CLEARANCES TO BUILDING AIR INTAKES AND |
| | OPENINGS INTO THE BUILDING, AND COMBUSTIBLE AND |
| | OVERHEAD CONSTRUCTION AS RECOMMENDED BY THE |
| | MANUFACTURER, AND IN ACCORDANCE WITH SECTION R303.5.1 |
| | FBC RES. THE BBQ GRILL SPECS HAVE BEEN SUBMITTED |
| | HOWEVER THE INSTALLATION MANUAL FOR THE GRILL IS |
| | RECOMMENDING THAT A RANGE HOOD BE INSTALLED BECAUSE OF |
| | THE BUILT-IN GRILL LOCATION ADJACENT TO THE HOUSE AND |
| | UNDER PERMANENT ROOF CONSTRUCTION. PLEASE SEE PAGE 15 |
| | OF THE USE AND CARE MANUAL- SECTION G2447.1 FBC RES. |
| | |
| | 3) FAILED. PROVIDE A GAS SUB-PERMIT APPLICATION- |
| | SECTION 105.1 WPB. PLEASE NOTE THE GAS SUB-PERMIT IS |
| | NO-FEE PRIOR TO PERMIT ISSUANCE, HOWEVER IT MAY BE |
| | DEFERRED TO A LATER DATE. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |