| Date |
Text |
| 2021-05-25 14:28:54 | FAILED |
| | |
| | PRIOR TO ZONING APPROVAL OF THIS PERMIT, YOU ARE |
| | REQUIRED TO HAVE AN ISSUED COMMUNICATION FACILITY |
| | PLACEMENT PERMIT - CITY RIGHTS-OF-WAY. THE PLANS |
| | INCLUDED WITH THIS ELECTRICAL PERMIT MUST MATCH THE |
| | PLANS APPROVED WITH THE AFOREMENTIONED PERMIT. THE |
| | COMMENTS BELOW WHERE PROVIDED AS PART OF THE |
| | COMMUNICATION FACILITY PLACEMENT PERMIT - CITY |
| | RIGHTS-OF-WAY AND APPLY FOR THE ECLECTIC PERMIT |
| | SUBMITTAL. |
| | |
| | 1) THE COVER SHEET "SCOPE OF WORK" CALLS OUT THAT THERE |
| | WILL BE AN ENCLOSURE CABINET. THIS POLE IS APPROVED TO |
| | BE A STEALTH POLE, WHICH DOES NOT PERMIT AN ENCLOSURE |
| | CABINET MOUNTED TO IT. |
| | |
| | 2) THE POLE STYLE AND HEIGHT MEET CITY REQUIREMENTS. |
| | THE POLE COLOR IS TO MATCH THE EXISTING DECORATIVE CITY |
| | LIGHT POLES (SPECKLED CONCRETE) LOCATED ON SOUTH |
| | FLAGLER DRIVE AND EVERNIA STREET. |
| | |
| | 3) THE POLE LOCATION IS APPROVED BY THE SPECIAL EVENTS; |
| | HOWEVER, THERE IS ARE DISCREPANCIES BETWEEN THE SURVEY |
| | AND SITE PLAN AND THE EQUIPMENT PLAN REGARDING THE POLE |
| | DIAMETER WHICH NEED TO BE CORRECTED SO PLANNING STAFF |
| | CAN VERIFY THAT THERE IS PROPER ADA CLEARANCE BETWEEN |
| | THE POLE AND THE EDGE OF PAVEMENT: |
| | |
| | A. THE STEALTH POLE SHOWN ON SHEET C3, ELEVATION AND |
| | EQUIPMENT PLAN, HAS A 14-INCH DIAMETER. THE SURVEY |
| | SHOWS A FOUR (4) INCH DIAMETER POLE. SHEET C2, SITE |
| | PLAN, DOES NOT CALL OUT THE DIAMETER OF THE POLE, BUT |
| | SEEMS TO MIRROR THE SURVEY. |
| | |
| | B. THE SURVEY AND THE SITE PLAN SHOW A SIDEWALK WIDTH |
| | OF FOUR (4) FEET PLUS A SIX (6) INCH CURB FOR A TOTAL |
| | OF 54 INCHES IN WIDTH. A 14-INCH DIAMETER POLE OFFSET 7 |
| | INCHES FROM THE EDGE OF THE RIGHT-OF-WAY RESULTS IN THE |
| | OUTSIDE EDGE OF THE POLE BEING 33 INCHES FROM THE |
| | TRAVEL LANE NOT 43 INCHES AS LISTED ON THE SURVEY. ADA |
| | REQUIRES A 36-INCH-WIDE FLUSH SURFACE, WHICH YOU DO NOT |
| | HAVE AT 33 INCHES. NOTE: THE FULL SIX (6) INCH CURB IS |
| | NOT CONSIDERED A FLUSH SURFACE SINCE THE OUTSIDE |
| | PORTION OF THE CURB SLOPES INTO A ROUNDED CONDITION |
| | WHERE IT TRANSITIONS TO THE ROADSIDE FACE OF THE CURB, |
| | SO YOU HAVE EVEN LESS THAN 33 INCHES AT THIS LOCATION. |
| | |
| | 4) FROM THE INFORMATION PRESENTED, THE 14-INCH DIAMETER |
| | POLE DOES NOT FIT AT THIS LOCATION. |
| | |
| | NOTE: A RIGHT-OF-WAY USE PERMIT FOR THE PLACEMENT OF |
| | THE POLE WITHIN THE RIGHTS-OF-WAY WILL BE REQUIRED |
| | PRIOR TO STARTING ANY WORK. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |
| | |