Plan Review Notes For Permit 21010594
Permit Number 21010594
Review Stop B
Sequence Number 1
Notes
Date Text
2021-02-05 13:49:40NEW SFR DETACHED GARAGE AND GUEST HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) PLEASE SHOW THE 2ND FLOOR GUEST HOUSE EXIT DOOR
 WIDTH TO COMPLY WITH R311.2 EGRESS DOOR.
 NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR
 EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE
 SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT
 LESS THAN 32 INCHES (813 MM) WHERE MEASURED BETWEEN THE
 FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90
 DEGREES (1.57 RAD). THE CLEAR HEIGHT OF THE DOOR
 OPENING SHALL BE NOT LESS THAN 78 INCHES (1981 MM) IN
 HEIGHT MEASURED FROM THE TOP OF THE THRESHOLD TO THE
 BOTTOM OF THE STOP.
 2) PLEASE SHOW THE SIDING AND FURRING ATTACHMENTS (TYPE
 OF ANCHOR, SIZE OF ANCHOR AND ON CENTER SPACING OF THE
 ANCHORS). FBC R703.1.2
 3) PLEASE DESCRIBE THE EXTERIOR WALL WATER PROOFING
 SHOWN ON DRAWING A-3 FBC R703.1.1
 4) PLEASE PROVIDE COMPLETE MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND
 ROOFING SYSTEM.
 5) ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD OR BE
 LISTED BY PRODUCT APPROVAL NUMBER ON THE DRAWINGS.
 6) THE CODE IN EFFECT CHANGED ON 1/1/2021 - PLEASE
 REVISE THE DRAWINGS TO REFLECT THE CODE IN EFFECT FOR
 THE BUILDING DESIGN (FBC 2020 AND ASCE 7-16)
 7) DRAWINGS SHOW AN EXISTING STRUCTURE - EXISTING
 STRUCTURE REQUIRES A SEPARATE BUILDING PERMIT FOR
 DEMOLITION - PLEASE PROVIDE THE DEMOLITION PERMIT
 NUMBER.
 8) ROOFING SYSTEM AND WINDOW/ DOOR PRODUCT APPROVALS
 MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE
 DEFERRED ON THE CONSTRUCTION DOCUMENTS - 107.3.4.1
 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION,
 DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF
 THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED
 SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
 REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL
 WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.