| Plan Review Notes For Permit 20121414 |
| Permit Number |
20121414 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-03-01 10:55:24 | GLASS FENCE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | | 1) DRAWING NEEDS TO SHOW THAT THE GLAZING WILL COMPLY | | | WITH FBC R308.3.1 IMPACT TEST. | | | WHERE REQUIRED BY OTHER SECTIONS OF THE CODE, GLAZING | | | SHALL BE TESTED IN ACCORDANCE WITH CPSC 16 CFR 1201. | | | GLAZING SHALL COMPLY WITH THE TEST CRITERIA FOR | | | CATEGORY II UNLESS OTHERWISE INDICATED IN TABLE | | | R308.3.1(1). FBC R308.4.4 GLAZING IN GUARDS AND | | | RAILINGS. | | | GLAZING IN GUARDS AND RAILINGS, INCLUDING STRUCTURAL | | | BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS, | | | REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE | | | SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION. | | | |
|