| 2021-03-08 15:53:03 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | PERMIT #20121326 |
| | |
| | 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | R101.5.1 FBC-ENERGY CONSERVATION. |
| | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL |
| | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED |
| | AGENT TO AVOID CONFLICT/DELAYS. |
| | |
| | THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED AND |
| | DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY |
| | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS |
| | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, |
| | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO |
| | BEGIN CONSTRUCTION. |
| | |
| | RESPONSE: |
| | A)ENERGY CALCULATIONS SUBMITTED WERE NOT SIGNED AND |
| | DATED BY THE OWNER OR LEGAL AGENT AS REQUESTED ON THE |
| | FIRST REVIEW. SEC. R103.1.1.2 FBC-ENERGY CONSERVATION |
| | |
| | B)FORM SUBMITTED R405-2020 IS FOR THE 2020 FBC EDITION. |
| | THIS PERMIT APPLICATION AND PLANS WERE REVIEWED UNDER |
| | THE 2017 FBC. NEED TO REVISE AND RESUBMIT FORM BASED ON |
| | THE 2017 FBC. |
| | CHAPTER 553 F.S. |
| | |
| | C)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF |
| | FORM. OWNER INFORMATION IS INCORRECT. PROVIDE BUILDER'S |
| | NAME. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | D)ITEM #2 ON PAGE 1 OF 5 IS INCORRECT. SEE QUESTION AND |
| | REVISE AS REQUIRED. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | E)ITEM #10 ON PAGE 1 OF 5 DOESN'T MATCH PLANS. SEE |
| | INSULATION NOTES ON SHEET A.1.1 AND REVISE AS REQUIRED. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | F)ITEM #11 ON PAGE 1 OF 5 DOESN'T MATCH PLANS. SEE |
| | INSULATION NOTES ON SHEET A.1.1 AND REVISE AS REQUIRED. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | G)ROOF TYPE ON PAGE 2 OF 5 IS INCOMPLETE. THERE ARE |
| | MORE ROOF TYPES IN THIS HOUSE. SEE PLANS AND REVISE AS |
| | REQUIRED. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | H)WINDOWS INFORMATION ON PAGE 4 OF 5 IS INCORRECT. SEE |
| | PLANS AND REVISE WINDOW ORIENTATION, WINDOW AREA, |
| | WINDOW OVERHANG DEPTH AND SEPARATION. |
| | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | I)BUILDER TO COMPLETE AND SIGN THE ENERGY PERFORMANCE |
| | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| | CONSERVATION. |
| | |
| | |
| | 2- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE |
| | FOLLOWING: |
| | R401.3 FBC-RESIDENTIAL. |
| | SEC. 107.2.5 CITY AMENDMENTS. |
| | SEC. 110.9 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REVISED SITE PLOT PLAN SHOWS A GRADE ELEVATION OF 20.70 |
| | AT THE NORTH EAST CORNER OF THE LOT. THERE IS NOT |
| | INFORMATION GIVEN ABOUT THE GRADE ELEVATION AT THE |
| | ADJACENT PROPERTY. WHAT WAS THIS ELEVATION BASED ON?. |
| | WHAT IS THE GRADE ELEVATION AT THE PROPERTY LINE? |
| | IN ADDITION, AFTER REVIEWING THE REVISED SITE PLOT PLAN |
| | IT WAS NOTICED THAT THE SIZE OF THE LOT IS SHOWN AS |
| | 55.90' X 100.00'. ACCORDING TO CITY PLAT RECORDS THE |
| | SIZE OF THIS LOT IS 54.9' X 100'. |
| | |
| | SINCE THERE IS DISCREPANCY ON THE SIZE OF THE LOT, A |
| | SURVEY WILL BE REQUIRED TO SHOW THE ACTUAL SIZE OF THE |
| | LOT AND TO SHOW THE ADJACENT GRADES TO VERIFY PROPOSED |
| | DRAINAGE. SEC. 107.2.5 CITY AMENDMENTS. |
| | |
| | NOTE: |
| | NEED TO CHECK SIZE OF PROPOSED STRUCTURE. PLANS SHOW A |
| | BUILDING WIDTH OF 40'-8". THIS SIZE OF BUILDING MAY NOT |
| | COMPLY WITH THE ZONING SETBACKS. COORDINATE WITH ZONING |
| | TO AVOID CONFLICTS/DELAYS. |
| | |
| | |
| | 3- OK |
| | |
| | 4- OK |
| | |
| | 5- OK |
| | |
| | 6-SHEET A.1: |
| | A)OK |
| | B)OK |
| | |
| | C) GROUND FLOOR ON SHEET A.1 SHOWS A PREFABRICATED |
| | PULL-DOWN ACCESS LADDER (22-1/2" X 54"). SPECIFY THE |
| | ADDITIONAL ATTIC LIVE LOADS AS REQUIRED BY TABLE R301.5 |
| | FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | INFORMATION REGARDING THE ADDITIONAL ATTIC LIVE LOAD |
| | FOR STORAGE AS REQUIRED BY TABLE R301.5 WAS NOT |
| | PROVIDED. |
| | |
| | |
| | 7- OK |
| | |
| | 8- PROVISO: TO BE SUBMITTED LATER AS DEFERRED |
| | SUBMITTAL. |
| | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 |
| | FOR |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO |
| | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT |
| | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL): |
| | |
| | A)OVERHEAD GARAGE DOOR. |
| | B)METAL ROOFING. |
| | C)ALL WINDOW TYPES SHOWN ON PLANS AND WINDOW SCHEDULES. |
| | D)ENTRY DOOR IF DIFFERENT THAN ALL OTHER EXTERIOR |
| | DOORS. |
| | E)OVERHEAD GARAGE DOOR |
| | |
| | 9- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | PRODUCT APPROVALS ALREADY SUBMITTED WERE NOT |
| | REVIEWED/APPROVED BY THE ARCHITECT OF RECORD. EITHER |
| | REVIEW AND APPROVED THOSE PRODUCT APPROVALS THAT WERE |
| | ALREADY SUBMITTED OR ALL THE PRODUCT APPROVALS CAN BE |
| | SUBMITTED AS DEFERRED SUBMITTAL AFTER THE PERMIT IS |
| | ISSUED TO AVOID CONFLICT/DELAYS. SEE PROVISO ON ITEM #8 |
| | ABOVE. |
| | |
| | 10- PROVISO: |
| | HOUSE IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT IS |
| | SPECIFYING R-30 SPRAY INSULATION. PROVIDE ICC |
| | EVALUATION REPORT FOR THE FOAM INSULATION TO VERIFY |
| | COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. |
| | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN |
| | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. |
| | |
| | 11- DEFERRED SUBMITTAL: |
| | A)PROVIDE GLAZED RAILINGS SHOP DRAWINGS (REVIEWED BY |
| | ARCHITECT OF RECORD). NOTE: TABLE R301.5 |
| | FBC-RESIDENTIAL. NEED A SAFETY FACTOR OF 4. SEE NOTE |
| | "H". |
| | |
| | B)BALCONY CABLE RAILINGS SHOP DRAWINGS (REVIEWED BY |
| | ARCHITECT OF RECORD). |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |