| 2021-01-07 14:40:36 | PLAN REVIEW / BUILDING |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER BUILDING - PX3169 |
| | PLANS EXAMINER 1&2 FAMILY - SFP306 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2014 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. SCOPE OF WORK APPEARS TO INCLUDE THE SUBSTANTIAL |
| | DEMOLITION OF THE EXISTING STRUCTURE. PROVIDE A DEMO |
| | PLAN. DETAIL WHAT IS BEIN DEMOLISHED. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | 2. DELETE - N/A |
| | |
| | 3. PROVIDE THE FINISHED FLOOR ELEVATION. |
| | R403.1.7.3 FOUNDATION ELEVATION. |
| | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| | ALL LOCATIONS ON THE SITE. |
| | |
| | 4. PROVIDE A SOILS REPORT. |
| | R401.4 SOIL TESTS. |
| | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL |
| | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, |
| | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE |
| | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL |
| | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE |
| | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. |
| | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN |
| | APPROVED METHOD. |
| | |
| | 5. PRODUCT APPROVALS INCLUDE 5 DOOR PRODUCT APPROVALS, |
| | 1 DOOR NOA, 3 WINDOW PRODUCT APPROVALS, 3 WINDOW NOA'S, |
| | CONCRETE ROOF TILE PRODUCT APPROVALS, METAL ROOFING |
| | PRODUCT APPROVALS, BAHAMA SHUTTER PRODUCT APPROVALS, |
| | PANEL WALL PRODUCT APPROVALS. |
| | DESIGNER SHALL REVIEW PRODUCT APPROVALS AND REMOVE ANY |
| | THAT DO NOT APPLY TO THIS PROJECT. |
| | DESIGNER SHALL SELECT SPECIFIC MODEL OF DOORS AND |
| | WINDOWS ON PRODUCT APPROVALS. IF NON-IMPACT RATED, |
| | PROVIDE OPENING PROTECTION/SHUTTER SCHEDULE AND SHUTTER |
| | PRODUCT APPROVALS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. |
| | |
| | 6. PROVIDE A WINDOW AND DOOR SCHEDULE. INCLUDE THE |
| | FOLLOWING: |
| | |
| | 6A) WINDOW SCHEDULE |
| | |
| | ITEM NUMBER/LOCATION ON |
| | PLAN/TYPE/MFGR./MATERIAL/GLASS/TREATMENT/ROUGH |
| | OPENING/IMPACT RESISTANT Y/N/PRODUCT APPROVAL |
| | NUMBER/NOA DESIGN PRESSURE RATING/OPENING REQUIRED |
| | PRESSURE RATING/EGRESS REQUIRED Y/N/SHUTTER REQUIRED |
| | Y/N |
| | |
| | 6B) DOOR SCHEDULE |
| | |
| | ITEM NUMBER/LOCATION ON |
| | PLAN/SIZE/THICKNESS/TYPE/MFGR./MATERIAL/JAM/ |
| | ROUGH OPENING/HARDWARE/NOA DESIGN PRESSURE |
| | RATING/OPENING REQUIRED PRESSURE RATING/SHUTTER |
| | REQUIRED Y/N |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |
| | |