Plan Review Notes
Plan Review Notes For Permit 20121129
Permit Number 20121129
Review Stop G
Sequence Number 1
Notes
Date Text
2021-01-20 14:49:221ST REVIEW FBC-2017 FUEL GAS
 PERMIT- 20121129
 1/20/2021
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P5.1 GAS RISER:
 A) SHOW THE METER AND THE GAS DELIVERY PRESSURE AT THE
 METER- SECTION 402.1 & 401.2 FBC FG.
 B) INDICATE THE TYPE OF GAS PIPING- SECTION 402.3 FBC
 FG.
 C) SHOW THE LOCATION OF THE REGULATOR AT THE WATER
 HEATER AND INDICATE THE REQUIRED GAS INPUT PRESSURE-
 SECTION 410.1 & 410.2 FBC FG.
  
 2) P5.1: PLEASE UPDATE THE FBC-2004 FUEL GAS CODE
 REFERENCE TO THE CODE IN FORCE FOR THIS PERMIT- 2017-
 SECTION 107.2.1 WPB.
  
 3) P0.1 & P5.1: PROVIDE A WATER HEATER EQUIPMENT
 SCHEDULE ON THE PLAN AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS- SECTION G2448.1 FBC FG AND TABLE C404.2
 FBC EC.
  
 4) PROVIDE A GAS SUB-PERMIT APPLICATION- SECTION 105.1
 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  