2021-03-22 11:05:01FIRE PROVISO:
  
 SMOKE ALARMS SHALL BE INSTALLED PER NFPA AND BE
 INTERCONNECTED
  
 31.3.4.5.3 IN BUILDINGS OTHER THAN THOSE EQUIPPED
 THROUGHOUT WITH AN
 EXISTING, COMPLETE AUTOMATIC SMOKE DETECTION SYSTEM OR
 A COMPLETE,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH 31.3.5,
 SMOKE ALARMS SHALL BE INSTALLED IN EVERY SLEEPING AREA
 IN
 ACCORDANCE WITH 9.6.2.10, AS MODIFIED BY 31.3.4.5.4.
 31.3.4.5.4 SMOKE ALARMS REQUIRED BY 31.3.4.5.3 SHALL BE
 PERMITTED TO BE
 BATTERY POWERED.
  
 9.6.2.10.8* IN NEW CONSTRUCTION, WHERE TWO OR MORE
 SMOKE ALARMS
 ARE REQUIRED WITHIN A DWELLING UNIT, SUITE OF ROOMS, OR
 SIMILAR AREA,
 THEY SHALL BE ARRANGED SO THAT OPERATION OF ANY SMOKE
 ALARM SHALL
 CAUSE THE ALARM IN ALL SMOKE ALARMS WITHIN THE DWELLING
 UNIT, SUITE
 OF ROOMS, OR SIMILAR AREA TO SOUND, UNLESS OTHERWISE
 PERMITTED BY
 ONE OF THE FOLLOWING:
 (1) THE REQUIREMENT OF 9.6.2.10.8 SHALL NOT APPLY WHERE
 PERMITTED BY ANOTHER SECTION OF THIS CODE.
 (2) THE REQUIREMENT OF 9.6.2.10.8 SHALL NOT APPLY TO
 CONFIGURATIONS THAT PROVIDE EQUIVALENT DISTRIBUTION OF
 THE
 ALARM SIGNAL.
 9.6.2.10.9 THE ALARMS DESCRIBED IN 9.6.2.10.8 SHALL
 SOUND ONLY
 WITHIN AN INDIVIDUAL DWELLING UNIT, SUITE OF ROOMS, OR
 SIMILAR AREA
 AND SHALL NOT ACTUATE THE BUILDING FIRE ALARM SYSTEM,
 UNLESS
 OTHERWISE PERMITTED BY THE AUTHORITY HAVING
 JURISDICTION.
  
 PLEASE ENSURE COMPLIANCE.
  