| Date |
Text |
| 2020-12-31 09:42:04 | 1ST REVIEW FBC-2017 MECHANICAL |
| | PERMIT-20120919 |
| | |
| | CODES IN EFFECT: |
| | |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| | 2017 |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| | EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) AS THIS IS A COMMERCIAL R-2 APARTMENT BUILDING THE |
| | MECHANICAL EQUIPMENT CALCULATIONS AND THE DESIGN OF THE |
| | MECHANICAL SYSTEM MUST HAVE AN ENGINEERS DIGITAL |
| | SIGNATURE AND SEAL OR THE MECHANICAL CONTRACTOR THAT |
| | HAS THE PERMIT TO DO THE JOB WOULD NEED TO PRINT AND |
| | SIGN THEIR NAME. FS 471;481 |
| | |
| | 2) AS THIS BUILDING IS AN R-2 OCCUPANCY THERE WILL BE |
| | SEPARATION AT THE FIRST FLOOR CEILING AND SECOND FLOOR. |
| | PLEASE SHOW A DETAIL OF AHU-1 AND AHU-2 AND THE BATH |
| | EXHAUST FANS WITH THE DUCTWORK PENETRATING THE RATED |
| | FLOOR CEILING ASSEMBLY AND THE PROTECTION AT THE |
| | PENETRATION. FBC M 607.6.2 |
| | |
| | 3) PLEASE PROVIDE EQUIPMENT SIZING CALCULATIONS FOR |
| | EACH APARTMENT. THE EQUIPMENT SIZING CALCULATIONS ARE |
| | FOR (1) 4.22 TON UNIT. FBC M 312.1 |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD |
| | SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER |
| | SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN |
| | THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS |
| | PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS |
| | PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR |
| | UPDATED. |
| | |
| | MICHAEL EDWARDS |
| | MECHANICAL EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL. 33401 |
| | 561-805-6728 |