| Plan Review Notes For Permit 20120919 |
| Permit Number |
20120919 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-01-05 15:30:53 | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) NO SMOKE ALARMS SHOWN, PLEASE SHOW ON PLANS R314 | | | | | | 2) BOTTOM UNITS TO HAVE AN OUTLET INSTALLED IN THE REAR | | | OF THE BUILDING ONE FOR EACH UNIT. 210.52 | | | | | | E3901.7 OUTDOOR OUTLETS. | | | NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY | | | ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6 | | | FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE | | | INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH | | | DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL. | | | BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM | | | INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE | | | BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE | | | LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE | | | THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)] | | | |
|